Advanced programming – SoundTraxx Tsunami Steam Users Guide User Manual
Page 62

Tsunami Steam Sound User’s Guide
Page 59
compensation at full speed such that the minimum load compensation level
at speed step 128 is:
(CV 10 - 128 )
Full Speed Load Compensation = -------------------
128
In general, you will want full load compensation at low speeds which
gradually reduces to zero load compensation at full throttle and may be
achieved by setting CV 10 to 126.
When operating in a consist, you may need to reduce the value in CV 212
which will reduce the low speed load compensation and avoid working
the locomotives against each other due to slightly different running
characteristics.
Advanced Programming
0 10 20 30 40 50 60 70 80 90 100 110 120 128
SPEED STEP
CV 212 = 255 & CV 10 = 0 (default)
PERCENT LO
AD COMPENSA
TION
CV 212 V
alue Sh
o
w
n in Red
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
255
225
200
175
150
125
100
75
50
25
0
CV 212
= 255
& CV 10
= 128
CV 212 = 255 & CV 10 = 10
0
CV 212 = 150
& CV 10 = 70