beautypg.com

Basics of programming, Programming procedure, Locking and unlocking cvs – SoundTraxx Tsunami Steam Users Guide User Manual

Page 13

background image

Tsunami Steam Sound User’s Guide

Page 10

Programming Procedure

As each DCC system is different, the procedure for programming a CV will

vary depending upon the system. Unfortunately, we cannot provide detailed

instructions to cover every command station and have to assume that you

have some level of understanding regarding it’s capabilities and operating

procedures. For specific programming procedures, please consult your DCC

system manual.

Locking and Unlocking CVs

The CV Lock/Unlock is a relatively new feature available in some DCC

decoders which allows you to program a decoder without the danger of

overwriting the programming in another. This especially useful in installations

where multiple decoders are used. For example, if you have installed a

function decoder in addition to the sound decoder, you may wish to lock the

CVs after programming to prevent accidentally programming one or the other.

To use the CV Lock feature implemented in CV 15 and 16, Bit 0 of CV 30

must first be set to 1 (the default value is 0). This is to avoid inadvertently

locking the decoder when the CV Lock feature is not needed.

CV 15 and 16 are used for locking and unlocking the decoder. CV 15 is

the Unlock Code and may be programmed to any value between 0 and

255 regardless of whether the decoder is locked or unlocked. CV 16 is the

Lock Code and may be set to any value between 0 and 7 but only when the

decoder is unlocked. Attempts to program CV 16 with a value greater than 7

will be ignored.

The decoder is unlocked when the value in CV 15 matches the value in CV

16. Otherwise the decoder is locked and can not be programmed in either

operations mode or service mode. Further, a locked decoder can not be reset

to its factory defaults until it is first unlocked. Tsunami decoders are shipped

from the factory with all CVs unlocked, that is, CV 15 and 16 are both set

to 0.

Note that if the decoder is unlocked, changing the value in CV 16 will

instantly lock the decoder. You must then set CV 15 to the same value as

was just programmed into CV 16 to unlock the decoder again.

If you decide to use the CV Locking feature for a multi-decoder installation,

each decoder installed inside that locomotive must first have its Lock Code

in CV 16 set prior to installation of any other decoders. Otherwise, all the

decoders will have the same Lock Code and the feature will not work. The

easiest way to go about this is to first install one decoder and program its

Lock Code. Then install the next decoder and program its Lock Code. Since

the first decoder is now locked it will be unaffected by the programming of

the second decoder (unless you accidentally set the Lock Code of the two

decoders to the same value. If this happens you will need to disconnect one

decoder and start over). Continue in this manner until all decoders have been

installed and their Lock Codes have been set.

Basics of Programming

This manual is related to the following products: