beautypg.com

Miscellaneous features – SoundTraxx Tsunami Steam Users Guide User Manual

Page 66

background image

Tsunami Steam Sound User’s Guide

Page 63

Automatic Bell - Tsunami can be programmed to turn the bell on and off at

preset speed points such as might occur when passing through a yard or

station platform.

Automatic Steam Release - This feature causes a short steam release to

sound whenever Tsunami is brought to a stop.

Automatic Brake Squeal - The brake squeal is activated by slowing the train

down by a predetermined amount.

These functions may be enabled by referring to Table M below and circling

the numbers corresponding to the sound function you want to enable. Then

add up the circled numbers and program this value into CV 197 (analog

mode) and or CV 198 (DCC mode). You can configure Tsunami so some or

all automated sounds work in one mode and not the other in any combination

as needed.

Then go on to set CVs 193-196 to fine tune the operation of each enabled

function.

Automatic Bell Set Points

CV 193 and 194 determine the speed steps (or equivalent throttle voltages

when operating in analog mode) at which the automatic bell turns on and off

respectively and may be set anywhere between 1 and 126 corresponding to

the speed step of the same value. CV 194, the bell off set point, must be set

to a value greater than CV 193 or else the bell will not turn on.

Example: Set CV 193 to 5 and CV 194 to 10. With these settings the bell

will initially be off when the engine is stopped. As the locomotive speed is

increased, the bell will turn on once the throttle setting reaches speed step

5. The bell will remain on so long as the engine is operated between speed

steps 5 and 10. Increasing the throttle beyond speed step 10 or below speed

step 5 will turn the bell back off. Once the bell has been turned off, it can be

turned back on by lowering the speed to the same setting as in CV 193.

Crossing Whistle Sensitivity

The automatic grade crossing whistle is activated whenever Tsunami senses

a sudden increase in the throttle setting (or track voltage in analog mode) as

set by the value in CV 195. This CV can be set to any value between 0 and

126 but for practical purposes, you will likely want a value between 3 and 10.

Too low a setting will result in the whistle going off at every speed increase

and too high a setting will require an extreme change in the throttle to trigger

the sound.

Miscellaneous Features

Automatic Grade

Crossing Enabled

Automatic

Bell Enable

Automatic Brake

Squeal

Automatic Steam

Blowdown

Automatic

Whistle Signal

Table M. Automatic Sound Function Enable

CV 197 (Analog Mode) or CV 198 (DCC Mode) Suggested Settings

16

4

2

1

8

This manual is related to the following products: