Rough-in (continued) a – Sloan 140 Royal / Regal Standard Concealed Flushometer User Manual
Page 3

3
MODEL 190
NOTE: Requires 1” I.P.S. (25 mm DN) SUPPLY
FIN.
FLOOR
FIN.
WALL
CENTER LINE
OF FIXTURE
4-3/4” (121 mm)
“L” DIM. 2-3/4” (70 mm)
+ WALL THICKNESS
13” (330 mm)
14-1/2” (368 mm)
1” I.P.S.
SUPPLY
(25 mm DN )
1-1/2” (38 mm)
OPENING
IN WALL
MODEL 192
NOTE: Requires 1” I.P.S. (25 mm DN) SUPPLY
FIN.
FLOOR
FIN.
WALL
CENTER LINE
OF FIXTURE
4-3/4” (121 mm)
“L” DIM. 2-3/4” (70 mm)
+ WALL THICKNESS
5” (127 mm)
14-1/2” (368 mm)
1” I.P.S.
SUPPLY
(25 mm DN )
1-1/2” (38 mm)
OPENING
IN WALL
2” (51 mm)
OPENING
IN WALL
MODEL 195
FIN.
FLOOR
FIN.
WALL
CENTER LINE
OF FIXTURE
CENTERLINE
OF WASTE
4-3/4” (121 mm)
“L” DIM. 2-3/4” (70 mm)
+ WALL THICKNESS
12” (305 mm)
13-1/2” (343 mm)
3/4” I.P.S.
SUPPLY
(20 mm DN )
1-1/2” (38 mm)
OPENING
IN WALL
MODEL 197
FIN.
FLOOR
FIN.
WALL
CENTER LINE
OF FIXTURE
CENTERLINE
OF WASTE
4-3/4” (121 mm)
“L” DIM. 2-3/4” (70 mm)
+ WALL THICKNESS
5” (127 mm)
13-1/2”
(343 mm)
7”
(178 mm)
3/4” I.P.S.
SUPPLY
(20 mm DN )
1-1/2” (38 mm)
OPENING
IN WALL
1” (25 mm)
OPENING
IN WALL
2” (51 mm)
OPENING
IN WALL
ROUGH-IN (CONTINUED)
A
For Sweat Solder applications,
slide Threaded Adapter onto
water supply pipe until end
of pipe rests against shoulder
of Adapter. Sweat solder the
Adapter to water supply pipe.
Install the Sloan Bak-Chek
®
Control Stop to the water
supply line with the outlet
positioned as required.
B
BAK-CHEK
®
CONTROL STOP
OUTLET
IRON PIPE NIPPLE
OR COPPER PIPE
WITH SWEAT
SOLDER ADAPTER
THREADED
ADAPTER
WATER
SUPPLY
PIPE
1 - INSTALL OPTIONAL SWEAT SOLDER ADAPTER (ONLY IF YOUR SUPPLY PIPE DOES
NOT HAVE A MALE THREAD) AND INSTALL CONTROL STOP
CONCEALED VALVES ARE SUPPLIED WITH DOUBLE HANDLE
OPENING TO ALLOW FOR INSTALLATION OF CONTROL STOP
ON EITHER THE LEFT OR RIGHT SIDE OF THE VALVE (REFER TO
ILLUSTRATION IN STEP 4).
NOTE