MODEL 140

MODEL 152

MODELS 143/144

MODEL 142

FIN.

FLOOR

CENTER LINE

OF FIXTURE

1” I.P.S.

SUPPLY

(25 mm DN )

CENTER LINE

OF WASTE

4-3/4”

(121 mm)

10”

(254 mm)

“L” DIM.

2-3/4” (70 mm)

+ WALL THICKNESS

1-1/2” (38 mm)
OPENING
IN WALL

2” (51 mm)
OPENING
IN WALL

4” (102 mm)

13” (330 mm)

14-1/2” (368 mm)

FIN.

FLOOR

FIN. WALL

CENTER LINE

OF FIXTURE

1” I.P.S.

SUPPLY

(25 mm DN )

CENTER LINE

OF WASTE

4-3/4”

(121 mm)

10”

(254 mm)

“L” DIM.

2-3/4” (70 mm)

+ WALL THICKNESS

1-1/2” (38 mm)
OPENING
IN WALL

2” (51 mm)
OPENING
IN WALL

5” (127 mm)

7-1/2”

(191 mm)

9” (229 mm)

FIN.

FLOOR

FIN.
WALL

CENTER LINE

OF FIXTURE

1” I.P.S.

SUPPLY

(25 mm DN )

CENTER LINE

OF WASTE

4-3/4”

(121 mm)

10”

(254 mm)

“L” DIM.

2-3/4” (70 mm) +

WALL THICKNESS

1-1/2” (38 mm)
OPENING
IN WALL

2” (51 mm)
OPENING
IN WALL

MODEL 143 - 14-1/2” (368 mm)
MODEL 144 - 10-1/2” (267 mm)

MODEL 143 - 13” (330 mm)

MODEL 144 - 9” (229 mm)

FIN.

FLOOR

FIN. WALL

CENTER LINE

OF FIXTURE

1” I.P.S.

SUPPLY

(25 mm DN )

CENTER LINE

OF WASTE

4-3/4”

(121 mm)

“L” DIM.

2-3/4” (70 mm)

+ WALL THICKNESS

1-1/2” (38 mm)
OPENING
IN WALL

2” (51 mm)
OPENING
IN WALL

22-1/2” (572 mm)

24” (610 mm)

MODEL 154

MODEL 153

FIN.

FLOOR

FIN. WALL

CENTER LINE

OF FIXTURE

1” I.P.S.

SUPPLY

(25 mm DN )

CENTERLINE

OF WASTE

4-3/4”

(121 mm)

“L” DIM.

2-3/4” (70 mm)

+ WALL THICKNESS

1-1/2” (38 mm)
OPENING
IN WALL

2” (51 mm)
OPENING
IN WALL

22-1/2” (572 mm)

24” (610 mm)

4” (102 mm)

FIN.

FLOOR

FIN. WALL

CENTER LINE

OF FIXTURE

1” I.P.S.

SUPPLY

(25 mm DN )

CENTER LINE

OF WASTE

17-1/2”

(445 mm)

4-3/4”

(121 mm)

“L” DIM.

2-3/4” (70 mm)

+ WALL THICKNESS

1-1/2” (38 mm)
OPENING
IN WALL

2” (51 mm)
OPENING
IN WALL

5” (127 mm)

24” (610 mm)

FIN.
WALL

NOTE: Water Closet Valves with

“-2.4” Model

Designation Deliver 2.4 gpf (9.0 Lpf)

ROUGH-IN

THIS PRODUCT CONTAINS MECHANICAL AND/OR

ELECTRICAL COMPONENTS THAT ARE SUBJECT TO

NORMAL WEAR. THESE COMPONENTS SHOULD BE

CHECKED ON A REGULAR BASIS AND REPLACED AS

NEEDED TO MAINTAIN THE VALVE’S PERFORMANCE.

!!! IMPORTANT !!!

WITH THE EXCEPTION OF THE CONTROL

STOP INLET, DO NOT USE PIPE THREAD

SEALANT OR PLUMBING GREASE ON

VALVE COMPONENTS OR COUPLINGS.

!!! IMPORTANT !!!