Rough-in – Sloan 140 Royal / Regal Standard Concealed Flushometer User Manual
Page 2

2
MODEL 140
MODEL 152
MODELS 143/144
MODEL 142
FIN.
FLOOR
CENTER LINE
OF FIXTURE
1” I.P.S.
SUPPLY
(25 mm DN )
CENTER LINE
OF WASTE
4-3/4”
(121 mm)
10”
(254 mm)
“L” DIM.
2-3/4” (70 mm)
+ WALL THICKNESS
1-1/2” (38 mm)
OPENING
IN WALL
2” (51 mm)
OPENING
IN WALL
4” (102 mm)
13” (330 mm)
14-1/2” (368 mm)
FIN.
FLOOR
FIN. WALL
CENTER LINE
OF FIXTURE
1” I.P.S.
SUPPLY
(25 mm DN )
CENTER LINE
OF WASTE
4-3/4”
(121 mm)
10”
(254 mm)
“L” DIM.
2-3/4” (70 mm)
+ WALL THICKNESS
1-1/2” (38 mm)
OPENING
IN WALL
2” (51 mm)
OPENING
IN WALL
5” (127 mm)
7-1/2”
(191 mm)
9” (229 mm)
FIN.
FLOOR
FIN.
WALL
CENTER LINE
OF FIXTURE
1” I.P.S.
SUPPLY
(25 mm DN )
CENTER LINE
OF WASTE
4-3/4”
(121 mm)
10”
(254 mm)
“L” DIM.
2-3/4” (70 mm) +
WALL THICKNESS
1-1/2” (38 mm)
OPENING
IN WALL
2” (51 mm)
OPENING
IN WALL
MODEL 143 - 14-1/2” (368 mm)
MODEL 144 - 10-1/2” (267 mm)
MODEL 143 - 13” (330 mm)
MODEL 144 - 9” (229 mm)
FIN.
FLOOR
FIN. WALL
CENTER LINE
OF FIXTURE
1” I.P.S.
SUPPLY
(25 mm DN )
CENTER LINE
OF WASTE
4-3/4”
(121 mm)
“L” DIM.
2-3/4” (70 mm)
+ WALL THICKNESS
1-1/2” (38 mm)
OPENING
IN WALL
2” (51 mm)
OPENING
IN WALL
22-1/2” (572 mm)
24” (610 mm)
MODEL 154
MODEL 153
FIN.
FLOOR
FIN. WALL
CENTER LINE
OF FIXTURE
1” I.P.S.
SUPPLY
(25 mm DN )
CENTERLINE
OF WASTE
4-3/4”
(121 mm)
“L” DIM.
2-3/4” (70 mm)
+ WALL THICKNESS
1-1/2” (38 mm)
OPENING
IN WALL
2” (51 mm)
OPENING
IN WALL
22-1/2” (572 mm)
24” (610 mm)
4” (102 mm)
FIN.
FLOOR
FIN. WALL
CENTER LINE
OF FIXTURE
1” I.P.S.
SUPPLY
(25 mm DN )
CENTER LINE
OF WASTE
17-1/2”
(445 mm)
4-3/4”
(121 mm)
“L” DIM.
2-3/4” (70 mm)
+ WALL THICKNESS
1-1/2” (38 mm)
OPENING
IN WALL
2” (51 mm)
OPENING
IN WALL
5” (127 mm)
24” (610 mm)
FIN.
WALL
NOTE: Water Closet Valves with
“-2.4” Model
Designation Deliver 2.4 gpf (9.0 Lpf)
ROUGH-IN
THIS PRODUCT CONTAINS MECHANICAL AND/OR
ELECTRICAL COMPONENTS THAT ARE SUBJECT TO
NORMAL WEAR. THESE COMPONENTS SHOULD BE
CHECKED ON A REGULAR BASIS AND REPLACED AS
NEEDED TO MAINTAIN THE VALVE’S PERFORMANCE.
!!! IMPORTANT !!!
WITH THE EXCEPTION OF THE CONTROL
STOP INLET, DO NOT USE PIPE THREAD
SEALANT OR PLUMBING GREASE ON
VALVE COMPONENTS OR COUPLINGS.
!!! IMPORTANT !!!