Sloan 111 Crown/Crown II Exposed Flushometer User Manual
Page 3

4
A
Slide Spud Coupling, Nylon Slip Gasket, Rubber Gasket and Spud
Flange over Vacuum Breaker Tube.
B
Insert Tube into Fixture Spud.
C
Hand tighten Spud Coupling onto Fixture Spud.
VACUUM
BREAKER
TUBE
SPUD COUPLING
NYLON SLIP
GASKET
RUBBER
GASKET
SPUD FLANGE
VACUUM
BREAKER
TUBE
SPUD COUPLING
NYLON SLIP
GASKET
RUBBER
GASKET
SPUD FLANGE
SPUD
COUPLING
NYLON
SLIP
GASKET
RUBBER
GASKET
SPUD
FLANGE
MODELS 111,
115, 116
MODEL 120
MODEL 180
MODEL 186
ELBOW FLUSH
CONNECTION
IF CUTTING VACUUM BREAKER TUBE TO SIZE, NOTE THAT CRITICAL LINE
(C/L) ON VACUUM BREAKER MUST TYPICALLY BE 6” (152 MM) ABOVE
FIXTURE. CONSULT CODE FOR DETAILS.
ON VALVES FURNISHED LESS VACUUM BREAKER, (XYV VARIATION),
CONNECT FLUSH TUBE TO THE BOTTOM OF THE VALVE USING THE SLIP
GASKET SUPPLIED.
NOTE
3 - INSTALL VACUUM BREAKER FLUSH CONNECTION
4 - INSTALL FLUSHOMETER
5 - INSTALL HANDLE ASSEMBLY
C
Align Flushometer body and securely tighten first the Tailpiece
Coupling
(1), then the Vacuum Breaker Coupling (2), and finally
the Spud Coupling
(3). Use a wrench to tighten these couplings in
the order shown.
B
Align flushometer directly
above the vacuum breaker
flush connection by sliding the
flushometer body IN or OUT as
needed. Tighten vacuum breaker
coupling by hand.
A
Lubricate tailpiece O-ring with water. Insert Adjustable Tailpiece
into Control Stop. Tighten Tailpiece Coupling by hand.
MAXIMUM ADJUSTMENT OF THE SLOAN ADJUSTABLE TAILPIECE IS 1/2”
(13 MM) IN OR OUT FROM THE STANDARD 4-3/4” (121 MM) (CENTERLINE
OF FLUSHOMETER TO CENTERLINE OF CONTROL STOP).
IF ROUGHING-IN MEASUREMENT EXCEEDS 5-1/4” (133 MM), CONSULT
FACTORY FOR LONGER TAILPIECE.
IF A GROUND JOINT TAILPIECE HAS BEEN SPECIFIED (RECOMMENDED
FOR SEAWATER APPLICATIONS), THERE IS NO LATERAL ADJUSTMENT;
THEREFORE, THE 4¾” (121 MM) ROUGH-IN MUST BE EXACT.
NOTE
C/L
FIXTURE
C/L
SUPPLY
TAILPIECE
COUPLING 1
FLUSHOMETER BODY
4-3/4”
(121 mm)
±1/2”
(13 mm)
SPUD
COUPLING
3
ADJUSTABLE
TAILPIECE
O-RING
G-44
FRICTION
RING
VACUUM
BREAKER FLUSH
CONNECTION
CONTROL
STOP
VACUUM
BREAKER
COUPLING
2
HANDLE TRIM RING
(CROWN II ONLY)
A-31 GASKET
HANDLE COUPLING
HANDLE
ASSEMBLY
USE A SLOAN A-50 SUPER
WRENCH™, SLOAN A-109
PLIER WRENCH OR SMOOTH
JAWED SPUD WRENCH TO
SECURE ALL COUPLINGS.
!!! IMPORTANT !!!
USE A SLOAN A-50 SUPER
WRENCH™, SLOAN A-109
PLIER WRENCH OR SMOOTH
JAWED SPUD WRENCH TO
SECURE HANDLE COUPLING.
!!! IMPORTANT !!!
A
Install handle assembly, handle trim Ring (Crown II flushometers
only), and gasket to flushometer body. Tighten handle assembly
securely.
FLUSHOMETER BODY
HANDLE TRIM RING
(CROWN II ONLY)
A-31 GASKET
HANDLE COUPLING
HANDLE ASSEMBLY