Prior to installation – Sloan 111 Crown/Crown II Exposed Flushometer User Manual
Page 2

2
WITH THE EXCEPTION OF CONTROL STOP INLET, DO NOT USE PIPE SEALANT
OR PLUMBING GREASE ON ANY VALVE COMPONENT OR COUPLING!
!!! IMPORTANT !!!
PROTECT THE FINISH OF SLOAN FLUSHOMETERS — DO NOT USE
TOOTHED TOOLS TO INSTALL OR SERVICE THESE VALVES. USE A SLOAN
A-50 SUPER-WRENCH™, SLOAN A-109 PLIER WRENCH OR SMOOTH
JAWED SPUD WRENCH TO SECURE ALL COUPLINGS. ALSO SEE “CARE
AND CLEANING” SECTION OF THIS MANUAL.
!!! IMPORTANT !!!
THIS PRODUCT CONTAINS MECHANICAL AND/OR ELECTRICAL
COMPONENTS THAT ARE SUBJECT TO NORMAL WEAR. THESE
COMPONENTS SHOULD BE CHECKED ON A REGULAR BASIS AND
REPLACED AS NEEDED TO MAINTAIN THE VALVE’S PERFORMANCE.
!!! IMPORTANT !!!
A
Measure from finished wall to C/L of Fixture Spud. Cut pipe 1¼” (32
mm) shorter than this measurement. Chamfer O.D. and I.D. of water
supply pipe.
WATER SUPPLY PIPE
FINISHED WALL
1-1/4”
(32 mm)
C/L OF
FIXTURE
SPUD
SWEAT
SOLDER
ADAPTER
B
Slide Threaded Adapter fully onto pipe.
C
Sweat solder the Adapter to pipe.
With the exception of Control Stop Inlet, DO NOT use pipe sealant or
plumbing grease on any valve component or coupling!
!!! IMPORTANT !!!
BAK-CHEK
®
CONTROL
STOP
COVER TUBE
IRON PIPE NIPPLE
OR COPPER PIPE
WITH SWEAT SOLDER
ADAPTER
SET SCREW
SUPPLY
FLANGE
WATER
SUPPLY PIPE
SWEAT
SOLDER ADAPTER
COVER TUBE
WALL
FLANGE
A
Measure from finished
wall to first thread of
Adapter or threaded
supply pipe (dimension
“X”). Cut Cover Tube to
this length.
B
Slide Cover Tube over
pipe. Slide Wall Flange
over Cover Tube until
against wall.
Thread Control Stop
onto pipe. Tighten with a
wrench.
C
Tighten Set Screw with a 1/16”
hex wrench. DO NOT install Vandal
Resistant Stop Cap at this time.
D
“X”
NEVER OPEN CONTROL STOP TO WHERE THE FLOW FROM THE VALVE
EXCEEDS THE FLOW CAPABILITY OF THE FIXTURE. IN THE EVENT OF A
VALVE FAILURE, THE FIXTURE MUST BE ABLE TO ACCOMMODATE A
CONTINUOUS FLOW FROM THE VALVE.
!!! IMPORTANT !!!
PRIOR TO INSTALLATION
Before you install the Sloan Crown II and Crown Flushometer, be sure the
items listed below are installed. Also, refer to the rough-in diagrams.
• Closet/urinal fixture
• Drain line
• Water supply line
IMPORTANT:
• ALL PLUMBING SHOULD BE INSTALLED IN ACCORDANCE WITH
APPLICABLE CODES AND REGULATIONS.
• WATER SUPPLY LINES MUST BE SIZED TO PROVIDE AN ADEQUATE
VOLUME OF WATER FOR EACH FIXTURE.
• FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS.
The Sloan Crown II and Crown Flushometer is designed to operate with 10
to 100 psi (69 to 689 kPa) of water pressure.
THE MINIMUM PRESSURE
REQUIRED TO THE VALVE IS DETERMINED BY THE TYPE OF
FIXTURE SELECTED. Consult fixture manufacturer for minimum pressure
requirements. Most Low Consumption water closets (1.6 gpf/6.0 Lpf)
require a minimum flowing pressure of 25 psi (172 kPa).
TOOLS REQUIRED FOR INSTALLATION
1 - INSTALL OPTIONAL SWEAT SOLDER ADAPTER (ONLY IF YOUR SUPPLY PIPE DOES NOT
HAVE A MALE THREAD)
2 - INSTALL COVER TUBE, WALL FLANGE AND CONTROL STOP TO SUPPLY PIPE
• Straight blade screwdriver
• Sloan A-50 Super-Wrench™, Sloan A-109 Plier Wrench or smooth jawed spud wrench