Prior to installation – Sloan 111 Crown/Crown II Exposed Flushometer User Manual

Page 2

background image

2

WITH THE EXCEPTION OF CONTROL STOP INLET, DO NOT USE PIPE SEALANT

OR PLUMBING GREASE ON ANY VALVE COMPONENT OR COUPLING!

!!! IMPORTANT !!!

PROTECT THE FINISH OF SLOAN FLUSHOMETERS — DO NOT USE

TOOTHED TOOLS TO INSTALL OR SERVICE THESE VALVES. USE A SLOAN

A-50 SUPER-WRENCH™, SLOAN A-109 PLIER WRENCH OR SMOOTH

JAWED SPUD WRENCH TO SECURE ALL COUPLINGS. ALSO SEE “CARE

AND CLEANING” SECTION OF THIS MANUAL.

!!! IMPORTANT !!!

THIS PRODUCT CONTAINS MECHANICAL AND/OR ELECTRICAL

COMPONENTS THAT ARE SUBJECT TO NORMAL WEAR. THESE

COMPONENTS SHOULD BE CHECKED ON A REGULAR BASIS AND

REPLACED AS NEEDED TO MAINTAIN THE VALVE’S PERFORMANCE.

!!! IMPORTANT !!!

A

Measure from finished wall to C/L of Fixture Spud. Cut pipe 1¼” (32

mm) shorter than this measurement. Chamfer O.D. and I.D. of water

supply pipe.

WATER SUPPLY PIPE

FINISHED WALL

1-1/4”

(32 mm)

C/L OF

FIXTURE

SPUD

SWEAT

SOLDER

ADAPTER

B

Slide Threaded Adapter fully onto pipe.

C

Sweat solder the Adapter to pipe.

With the exception of Control Stop Inlet, DO NOT use pipe sealant or

plumbing grease on any valve component or coupling!

!!! IMPORTANT !!!

BAK-CHEK

®

CONTROL

STOP

COVER TUBE

IRON PIPE NIPPLE

OR COPPER PIPE

WITH SWEAT SOLDER

ADAPTER

SET SCREW

SUPPLY

FLANGE

WATER

SUPPLY PIPE

SWEAT

SOLDER ADAPTER

COVER TUBE

WALL

FLANGE

A

Measure from finished

wall to first thread of

Adapter or threaded

supply pipe (dimension

“X”). Cut Cover Tube to

this length.

B

Slide Cover Tube over

pipe. Slide Wall Flange

over Cover Tube until

against wall.

Thread Control Stop

onto pipe. Tighten with a

wrench.

C

Tighten Set Screw with a 1/16”

hex wrench. DO NOT install Vandal

Resistant Stop Cap at this time.

D

“X”

NEVER OPEN CONTROL STOP TO WHERE THE FLOW FROM THE VALVE

EXCEEDS THE FLOW CAPABILITY OF THE FIXTURE. IN THE EVENT OF A

VALVE FAILURE, THE FIXTURE MUST BE ABLE TO ACCOMMODATE A

CONTINUOUS FLOW FROM THE VALVE.

!!! IMPORTANT !!!

PRIOR TO INSTALLATION

Before you install the Sloan Crown II and Crown Flushometer, be sure the

items listed below are installed. Also, refer to the rough-in diagrams.
• Closet/urinal fixture
• Drain line
• Water supply line

IMPORTANT:

• ALL PLUMBING SHOULD BE INSTALLED IN ACCORDANCE WITH

APPLICABLE CODES AND REGULATIONS.

• WATER SUPPLY LINES MUST BE SIZED TO PROVIDE AN ADEQUATE

VOLUME OF WATER FOR EACH FIXTURE.

• FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS.

The Sloan Crown II and Crown Flushometer is designed to operate with 10

to 100 psi (69 to 689 kPa) of water pressure.

THE MINIMUM PRESSURE

REQUIRED TO THE VALVE IS DETERMINED BY THE TYPE OF

FIXTURE SELECTED. Consult fixture manufacturer for minimum pressure

requirements. Most Low Consumption water closets (1.6 gpf/6.0 Lpf)

require a minimum flowing pressure of 25 psi (172 kPa).

TOOLS REQUIRED FOR INSTALLATION

1 - INSTALL OPTIONAL SWEAT SOLDER ADAPTER (ONLY IF YOUR SUPPLY PIPE DOES NOT

HAVE A MALE THREAD)

2 - INSTALL COVER TUBE, WALL FLANGE AND CONTROL STOP TO SUPPLY PIPE

• Straight blade screwdriver
• Sloan A-50 Super-Wrench™, Sloan A-109 Plier Wrench or smooth jawed spud wrench