Pat 2000i – Seaward PAT2000i User Manual
Page 29
Appendix C:
EARTH LEAKAGE LIMITS
STANDARD
Class I
Class ll
Hand held /
Stationary
portable
BS3456
Household Electrical
0.75 mA
0 75mA or
0.25mA
(2)
Appliances
0.75mA / KVA
(1)
Clause 16.2
BS4533
Luminaries
1.0 mA
N/A
0.5mA
Clause 10.3
BS2769
Hand held motor
0.75 mA
N/A
0.25mA
operated tools
Clause 12
EN60950 Information technology
0 75 mA
3.5 mA
[3]
0.25mA
equipment
Clause 5.2
NOTES:
[1] For heating elements 0.75mA or 0.75mA / KVA with a maximum of 5mA.
[2] If protected against moisture; ordinary appliance 5.0mA, others 3.5mA.
[3] Stationary equipment connected by a BS EN60309-2 connector may have
a maximum leakage current of 5% of input current per phase.
Due to a policy of continuous development Seaward Electronic Limited reserves the right to alter the equipment
specification and description outlined in this publication without prior notice and no part of this publication shall
be deemed to be part of any contract for the equipment unless specifically referred to as an inclusion within such
contract.
221A564 - A
PAT 2000i
Portable Appliance Tester
26