Appendix C:

EARTH LEAKAGE LIMITS

STANDARD

Class I

Class ll

Hand held /

Stationary

portable

BS3456

Household Electrical

0.75 mA

0 75mA or

0.25mA

(2)

Appliances

0.75mA / KVA

(1)

Clause 16.2

BS4533

Luminaries

1.0 mA

N/A

0.5mA

Clause 10.3

BS2769

Hand held motor

0.75 mA

N/A

0.25mA

operated tools
Clause 12

EN60950 Information technology

0 75 mA

3.5 mA

[3]

0.25mA

equipment
Clause 5.2

NOTES:

[1] For heating elements 0.75mA or 0.75mA / KVA with a maximum of 5mA.

[2] If protected against moisture; ordinary appliance 5.0mA, others 3.5mA.

[3] Stationary equipment connected by a BS EN60309-2 connector may have

a maximum leakage current of 5% of input current per phase.

Due to a policy of continuous development Seaward Electronic Limited reserves the right to alter the equipment
specification and description outlined in this publication without prior notice and no part of this publication shall
be deemed to be part of any contract for the equipment unless specifically referred to as an inclusion within such
contract.