RJS Inspector D4000 Auto Optic (FIRMWARE version A.05 and Earlier) User Manual
Page 33
Operator
’
s Guide
Inspector 4000
™
002-5564
RJS, Minneapolis, MN
26
Press Select to bring up the next screen.
Bar width deviations are represented graphically on the display.
-100 % Tol. +100%
-------++RRARR+++++
“R” letters represent “range.”
“A” represents the average of all character bar width deviations.
Note: The location of the “A” is indicated with the 5 LEDs also.
See Table 9-A.
The closer the “A” is to the center of the display, the better. The following shows the
percentage of the scanning tolerance at each position on the display:
-
93
-
79
-
65
-
50
-
36
-
22
-
8
-
1
0
+
8
+
22
+
36
+
50
+
65
+
79
+
93
Negative numbers to the left indicate bars that are narrower.
Positive numbers to the right indicate bars that are wider.
The closer the “A” is to the edge, the more likely the Reject.