RJS Inspector D4000 Auto Optic (FIRMWARE version A.05 and Earlier) User Manual
Page 32
![background image](https://www.manualsdir.com/files/802937/content/doc032.png)
Operator
’
s Guide
Inspector 4000
™
002-5564
RJS, Minneapolis, MN
25
Press Select to bring up the next screen:
Mod Check is : 5
S/B : 5 Pass
This display indicates (when applicable) the Mod check character decoded and the
Mod check character that should have been decoded (expected) in the symbol. PASS
or FAIL is also indicated.
For Code 128, the Mod check character is displayed as the symbology’s character
value (a number from 000 to 102). One or two numeric Mod check characters may
precede the 3-digit Code 128 Mod check described above. These digits represent the
Mod 10 check character(s) that can be included depending on the format.
Code 93 will display 2 Mod check characters. See Appendix B for Code 93 character
representations.
Press Select to bring up the next screen:
Code 3of9
Acceptable
Symbology type is indicated on the top row and the analysis overview on the bottom
row.