RJS Inspector D4000 Auto Optic (FIRMWARE version A.05 and Earlier) User Manual
Page 22
![background image](https://www.manualsdir.com/files/802937/content/doc022.png)
Operator
’
s Guide
Inspector 4000
™
002-5564
RJS, Minneapolis, MN
15
1.
When Companion is enabled, data output is in the format of analysis only.
2.
When Computer is enabled, data is output in computer readable format (text and
graphics
). See Appendix C,
Computer Mode.
The next
selection
is:
Scans/Analysis
Single
From this screen you
may
choose the number of scans (from 1 (single) to 10) to be used
in
the analysis.
The next selection is
Decode
3of9 as:
Decode 3of9 as
ANSI 3of9
This
selection
is for choosing the Code 39 sub-specifications for analysis:
ANSI 3 of 9
3of9
w/43
AIAG B-1
AIAG B-3/4/5
LOGMARS
HIBC 3 of 9
Press Select to choose an option.
Press Enter to initiate processing for that option.
If either AIAG choice is entered, the Inspector 4000 will automatically perform the scan
reflectance profile analysis per the AIAG grading thresholds and display numbers 4, 3, 2,
1 and 0 in place of the letter grades.