No output in large screen, Confirm if there are any input singles, Confirm if single output – RGBLink VSP 3500 User Manual User Manual
Page 103: Large screen output flash point, Confirm if preview output is normal, Large screen only display part of the image, Signal need to scale, Common questions and solution
7. Common Questions and Solution
VSP 3500 User Manual 103
Confirm if there are any input singles
Press 【MENU】to find "Device information" , check if the INPUT signal is
normal via 【 NEXT 】, if suggest "NO INPUT", means no signal. Check
the front-end signal line, please note do double show or expand for
computer. Can enter other formats signal to do the same operation.
Confirm if single output
Find a display with DVI input, connect to the corresponding output port of
processor, check whether the signal is correct on the monitor. If not
display properly, please check whether there is input signal, or if input
wire interface is taken tight, output wire interface is picked up tightly. If
display normally, check if sending card is normally working or need to
replace sending card test.
Large Screen Output Flash Point
Confirm if preview output is normal
Find a display with DVI input, connect to the corresponding output port of
processor, check whether the signal is correct on the monitor. If display
normally shows and no flash point, please check whether DVI outlets put
tight or replace to DVI line of sending card. If display flash point, please
judge if input signal, wire, and interface is normal.
Large Screen only Display Part of the
Signal need to scale
Press 【SCALE】, rotate the knob to adjust the size of screen size,
including "Width", "Height" etc. Press【NEXT】to confirm.