To Perform a Complete RC2500 System Reset
1. This procedure should be followed only in the case of the requirement to bring the unit software to its
factory shipped condition. (e.g. in the event of changing antenna sites) Resetting the RC2500 has
the effect of deleting all satellites in memory and returning all CONFIG mode items to their factory
state.
2. If any data from the previous installation is required, be sure to log it on the RC2500 Non-Volatile
Memory Items Worksheet. (See Steps 1 and 2 above.)
3. From CONFIG Mode, scroll to the RESET SYSTEM DATA item. Key in the 6 digit code “41758”
followed by the ENTER key. The Controller will return in Manual Mode. All CONFIG mode items will
be reset to their factory state. All stored satellites will be deleted from memory. The Date and Time
will remain unchanged.
To Convert the RC2500 from 115VAC to 230VAC Operation:
Switch the power off at the front panel. Remove the IEC power cord from the back panel power entry
module. With a small straight-blade screwdriver, remove the fuse drawer from the power entry module.
With the same tool, remove the small plastic circuit card. Rotate the card so that the desired operating
voltage will be displayed through the front of the fuse drawer and reinsert the card so that it firmly seats
into the power entry module. Replace the fuse with one of the appropriate size for the new operating
mains voltage (fuse ratings may be found in the manual and on a back panel placard).