RC2500 Antenna Controller

Appendix N

Replacing the NPL 9000

Research Concepts, Inc. • 5420 Martindale Road • Shawnee, Kansas • 66218-9680 • USA

www.researchconcepts.com

Auxiliary I/O Connection

J6, located directly above J7, is the Auxiliary I/O connector. This port, based on a DB-25 receptacle,

supports isolated, axis-specific limit inputs (unused) as well as contact closures for summary faults and

peripheral equipment control. A +5 VDC regulated output (200mA max), a +24 VDC unregulated output

(1 Amp max), and an analog voltage input, all referenced to the RC2500 ground, are also available The

individual pin definitions are shown in the table below. Both J6 and J7 are required when operating with

the NPL 9000 Antenna Drive Unit (ADU).

RC2500 Pin #
& (resource #)

Description

NPL9000 ADU Pin #

1 (PC3)

Summary Fault dry contact COM, (3A @ 125VAC or 3A

@ 30VDC).

Unused

2 (PC3)

Summary Fault dry contact NO, (3A @ 125VAC or 3A @

30VDC).

Unused

3 (PB1)

unused input return

No connect

4 (PB0

HSI.1,P2.4)

unused input return

No connect

5 (PB2)

unused input return

No connect

6 (PB3)

unused input return

No connect

7 (PB5)

unused input return

No connect

8 (PB4)

unused input return

No connect

9

Drive Common (return path for AZ, EL, & POL drive

command lines)

No connect

10 (PC0)

PC0 output dry contact NC, (3A @ 125VAC or 3A @

30VDC). (dedicated pin….Do Not Use)

dedicated pin, do not use.

11 (P0.2)

P0.2 Auxiliary analog/digital input 0 - +5 VDC.

Unused

12

Ground (for digital/analog I/O).

Unused

13

Ground for system bus voltages.

Unused

14 (PC3)

Summary Fault dry contact NC, (3A @ 125VAC or 3A @

30VDC).

Unused

15 (PB1)

unused input

No connect

16 (PB0)

unused input (same as J7-10)

No connect

17 (PB2)

unused input

No connect

18 (PB3)

unused input

No connect

19 (PB5)

unused input

No connect

20 (PB4)

unused input

No connect

21 (PC1)

unused output

No connect

22 (PC0)

PC0 output dry contact COM, (3A @ 125VAC or 3A @

30VDC). (dedicated pin….Do Not Use)

dedicated pin, do not use.

23 (PC0)

PC0 output dry contact NO, (3A @ 125VAC or 3A @

30VDC). (dedicated pin….Do Not Use)

dedicated pin, do not use.

24

+5 Volts DC digital power, 200mA max.

Unused

25

Unregulated +24 VDC bus voltage, 0.3 Amp max..

Unused

Once the above connections have been made, verify that antenna motion in the appropriate direction can

be affected from the front panel in MANUAL mode. You may now continue the RC2500 installation with

sections 3.3.3 through 3.5.