RC2500 Pin #
& (resource)
Description
83MC4 Pin #
(0.4V = direction CCW)
2
Drive Ground (return path for AZ, EL, & POL drive
command and limit status lines)
DRIVE GND TB3-1,2
3 (PA0)
Azimuth Enable, pull-down drive, 700mA max sink. (0.4V
= AZ move)
AZ EN TB3-3
4 (PA4)
Elevation Enable, pull-down drive, 700mA max sink.
(0.4V = EL move)
EL EN TB3-7
5
Drive Ground (return path for AZ, EL, & POL drive
command and limit status lines)
DRIVE GND TB3-1,2
6 (PA3)
Azimuth Brake, solid state drive, 700mA max sink. (0.4V
= AZ Brake release)
AZ BRK TB3-6
7 (PA7)
Elevation Brake, solid state drive, 700mA max sink. (0.4V
= EL Brake release)
EL BRK TB3-10
8
Drive Ground (return path for AZ, EL, & POL drive
command and limit status lines)
DRIVE GND TB3-1,2
9 (PA6)
EL Slew, solid state drive, 700mA max sink. (PC1 0.4V =
EL Fast Slew)
EL SLEW TB3-??
10 (PB0)
Azimuth CCW Limit Status input, 24 VDC low
current.(same as J6-16) not used here.
No connect
11
nc
12
nc
13
nc
14 (P2.4)
Azimuth Interlock Status input, 24 VDC low current. (0V =
AZ fault)
AZ INTLK TB3-17
15 (HSI.1)
Elevation Interlock Status input, 24 VDC low current. (0V
= EL fault)
EL INTLK TB3-20
16 (PB7)
Drive Ground (Emergency Stop status return)
DRIVE GND TB3-1,2
17 (PB0,
HSI.1, P2.4)
Drive Ground (Interlock Status and Az CCW Lim return;
same as J6-4)
DRIVE GND TB3-1,2
18 (PB0,
HSI.1, P2.4)
Drive Ground (Interlock Status and Az CCW Lim return;
same as J6-4)
DRIVE GND TB3-1,2
19 (PB7)
System Interlock Status Input, 24 VDC low current.
(ESTOP input, 0V = Emergency STOP)
SYSTEM INTLK TB3-16
20
Nc
21 (PA2)
AZ Slew, solid state drive, 700mA max sink. (0.4V = AZ
Fast Slew)
AZ SLEW TB3-??
22 (PA5)
Elevation Direction, pull-down drive, 700mA max sink.
(0.4V = move DOWN)
EL UP/DWN TB3-8
23 (PC2)
Polarization Enable, pull-down drive, 700mA max sink.
(0.4V = POL move)
POL EN TB3-??
24 (PB6)
System Interlock status input, 24 VDC low current. (0V =
ESTOP or Interlock open)
SYSTEM INTLK
TB3-16
25 (PB6)
ACU / Local Status input, low current return path (0V =
Local Pedestal controls active.)
ACU/LOCAL STATUS
TB3-13
In addition to a Maintenance status indication, the Voltage on pin 24 is used to power the electronic
components that reside on the A.I.U.-side of the opto-isolation barrier. When no System Interlock Input is
present, this pin must still be powered by between +15 and +28V (and its return line connected to “-“) in