Appendix O
Replacing the Andrew APC100/ APC 300 143
Research Concepts, Inc. • 5420 Martindale Road • Shawnee, Kansas 66218-9680 • USA
www.researchconcepts.com
a) Record the value of the display offset associated with the axis.
b) Reset the display offset associated with the axis by entering 0.0 at the appropriate CONFIG
mode prompt.
c) Reset the lower limit associated with the axis (azimuth CCW, elevation down, or polarization
CCW) by entering 0.0 at the appropriate CONFIG mode prompt.
d) If resetting the azimuth limits set the Azimuth CW Limit to 359.99. If resetting the elevation or
polarization limits, set the Elevation Up Limit or Polarization CW Limit to –0.01.
e) Reinitialize the offset associated with the axis whose limits are being reset to the value
recorded in step a above.
Rc25_lmkds_add.doc completed 4.2.00 by SMM