beautypg.com

2 technical data, 1 unit data, Technical data 2.1 unit data – REMKO RBW 300 PV User Manual

Page 7: 2technical data

background image

2

Technical data

2.1 Unit data

Series

RBW 300 PV

RBW 300 PV-S

Function

Domestic hot-water heating

System

Air / water heat pump

Drinking water tank enamelled, gross volume

l

Series 300

Drinking water tank enamelled, net volume

l

287

280

Auxiliary heater / rated output

kW

Series / 1.5

Usable limits, heating

°C

-7 to +40

Min./max. Water temperature

°C

38 / 60

Heating capacity with A7/W50

kW

1.8

COP per EN 255-3 / COP with A7/W50

1)

COP

3.7

COP per EN 16147 / COP with A7/W50

1)

COP

2.61

Power supply

V / ~ / Hz

230 / 1/ 50

Electrical rated power consumption

kW

0.46

Max. rated power consumption

kW

2.06

Rated current consumption

A

8.92

Max. current consumption

A

9.0

Refrigerant / basic capacity

-- / kg

134A

2)

/ 0.95

Fuse protection prov. by the customer (p. outdoor unit)

A slow-

acting

16

Sound power level/sound pressure 1m hemispherical

dB(A)

53/45

Max. airflow volume

m³/h

350

Min. flow volume

m³/h

175

Max. operating pressure

bar

7

Air duct connection

mm

145

Hydraulic connection, water-side

Inches

IG 3/4"

Condensate-drain socket

Inches

IG 1/2"

Max. permissible air-side pressure loss

kPa

50

Pipe length supply/exhaust duct max. (at 150 mm)

m

6/6

Dimensions (diameter/height/tilt height)

mm

650/1870/1920

Enclosure class

--

IP X1

Weight

kg

136

141

1)

COP = coefficient of performance (heating capacity figure)

2)

Contains greenhouse gas according to Kyoto protocol, GWP 1975

For technical details regarding the integrated heat exchanger see overleaf.

7