Parameter description

Para-

meter

Designation

Description

d01

Start defrost temperature (evaporator)

If the evaporator temperature is < d01 then the

defrosting process starts

d02

End defrost temperature (evaporator)

If the evaporator temperature is > d02 then the

defrosting process ends

d03

Time between defrosts

This is the min. run-time of the heat pump

between 2 defrosting processes

d04

Max. defrosting period

Once the set time d04 lapses, defrosting ends

g02

Duration of legionella function

Time of the legionella function

g03

Time start of legionella function

The legionella function starts at this time

g04

Time interval (day) of legionella function

The legionella function is activated at this

interval (number of days)

n10

Max. storage tank temperature solar pump stop

If the storage tank temperature is higher than

n10, the solar pump r06 stops: Switch-on delay

electrical heating coil. Upon exceeding the set

run-time r06, the electrical heating coil is

switched on