Error codes and their meanings

Code Error description

Cause

Remedial measures

P01

Probe, storage tank bottom,

defective

Defective or short-circuited.

Plug-in contact not correct

Check probe resistance.

Replace probe

P02

Probe, storage tank top, defec-

tive

P034 Probe, collector defective

P04

Probe, ambient air defective

P05

Probe, evaporator defective

P07

Probe, suction pipe defective

E01

High pressure fault

Refrigerant pressure is too

high, pressure switch has trig-

gered

Check pressure, water temper-

ature too high

E02

Low pressure alarm

Refrigerant pressure is too low,

pressure switch has triggered

Check pressure, refrigerant

deficiency

E03

Overheating error

Water level too low

Check water level

E08

Communication fault

Communication error between

operating unit and motherboard

Cable connection, check plug-

in contacts