6 hydraulic connection, Hydraulic connection, Remko rbw – REMKO RBW 300 PV User Manual
Page 16: 6hydraulic connection

6
Hydraulic connection
Hydraulic connection drawings
All components and safety devices must be provided by the customer.
A
B
C
D
E
F
1
2
3
1
4
5
6
7
8
9
8
10
11
Fig. 7: Hydraulic connection drawings
A: Cold water inlet
B: Inlet 2nd heat generator
C: Return flow 2nd heat generator
D: Condensate drain
E: Hot water outlet
F: Hot water
1:
Shut-off valve
2:
Storage tank recharging (by oil, gas or solar)
3:
Flap valve
4:
Immersion sleeve (for oil, gas or solar)
5:
Storage tank emptying
6:
Electric heating coil
7:
Circulation pump
8:
Flap valve
9:
Safety valve, 6 bar
10: Safety temperature limiter
11: Magnesium anode
CAUTION!
If no circulation is connected then the circula-
tion connection nozzles must be sealed water-
tight.
REMKO RBW
16
This manual is related to the following products: