6

Hydraulic connection

Hydraulic connection drawings

All components and safety devices must be provided by the customer.

A

B

C

D

E

F

1

2

3

1

4

5

6

7

8

9

8

10

11

Fig. 7: Hydraulic connection drawings

A: Cold water inlet

B: Inlet 2nd heat generator

C: Return flow 2nd heat generator

D: Condensate drain

E: Hot water outlet

F: Hot water

1:

Shut-off valve

2:

Storage tank recharging (by oil, gas or solar)

3:

Flap valve

4:

Immersion sleeve (for oil, gas or solar)

5:

Storage tank emptying

6:

Electric heating coil

7:

Circulation pump

8:

Flap valve

9:

Safety valve, 6 bar

10: Safety temperature limiter

11: Magnesium anode

CAUTION!

If no circulation is connected then the circula-

tion connection nozzles must be sealed water-

tight.