beautypg.com

Run/stop, Single, Copy – OWON TDS Series User Manual

Page 63

background image

5.Advanced User Guidebook

58

Function Items

Setting

Acquisition Mode

Current

Vertical Coupling

DC

Vertical Scale

Adjust to the proper division.

Bandwidth

Full

Horizontal Level

Middle

Horizontal Sale

Adjust to the proper division

Trigger Type

Adjust to the proper type

Trigger Source

Show the minimum number of channels.

Trigger Coupling

DC

Trigger Slope

Current

Trigger Level

Mid-point Setting

Trigger Mode

Auto

Display Format

YT

Run/Stop:

Enable or disable sampling on input signals.

Notice: When there is no sampling at STOP state, the vertical division and
the horizontal time base of the waveform still can be adjusted within a
certain range, in other words, the signal can be expanded in the horizontal or
vertical direction.

Single:

Press this button you can set the trigger mode as single directly, so

when

trigger occurs, acquire one waveform then stop.

Copy:

You can save the image, waveform data or setup file by just pressing the
Copy button.

After you have defined the save parameters with the Save

menu, you can save files with a single push of the Copy button. For more
details, please see "To save with Copy button push" on P44.