Dome control protocol setting – OpenEye CM-511 Installation Manua User Manual
Page 19
![background image](https://www.manualsdir.com/files/800237/content/doc019.png)
29243AC
19
Dome Control Protocol Setting
Define the protocol you are going to use based on the devices of your surveillance system. Generally, use one
protocol even if the devices are provided by different manufacturers. Use the switch to set your dome control
protocol and the baud rate. Refer to the table below and turn the arrow to choose a protocol for your speed
dome.
Switch No.
Protocol
Baud Rate
00
VCL 9600
01
Pelco D
2400
02
Pelco P
4800
04
Chiper 9600
05
Philips 9600
07
OPTIX 3
9600
08
AD422 4800
09
DM P
9600
11
Pelco D
4800
12
Pelco D
9600
13
Pelco P
2400
14
Pelco P
9600
15
JVC 9600
21
Kalatel-485 9600
22
Kalatel-422 4800
Example To set the protocol Pelco D, with switch no. 1 and baud rate 2400,
the protocol switch should be set as at right.
Note
The number 0 should be at the top, as shown, when setting the
camera ID.