against being started up again by mistake, and
Nortec Systems should be
informed. This can be the case under any of the following circumstances:
-
when one or more components of the system have been damaged,
-
when the system no longer works properly
-
when connections or lines leak.
-
The electrical system components (PerPur, DE 3-5) are IP00 protected. Take care
that they are protected against dripping and sprayed water at their locations.
CAUTION: If the System is installed in a room that has no water drain, then water
sensors with automatic cut-off valves must be installed to shut off the water supply
in case of damage to the system which conducts water.
-
To avoid damage from water you should not store any water sensitive materials di-
rectly under system components.
-
The Clear Water System may o n ly be operated with softened water (0-1°dH, 17
ppm). Well water and rain water are not suitable. The water supply must be virtually
germ free.
-
If the pure water (generated by water softener and pure water system) is used for
an air humidification system, a greater or lesser amount of mineral deposits can
accumulate in the vicinity of the aerosol mist. Sensitive materials and devices are to
be taken away from this area or protected accordingly.
-
Except for the work described in these instructions, no invasive operation of any
kind may be carried out on the Pure Water System.
-
Only use original accessories and spare parts from DRAABE.
-
Except with the written permission of DRAABE, no changes may be made to the
Pure Water System.
-
In the event of changes to the system, an acceptance procedure is to be carried out
by the
Nortec Systems customer service or other person authorized by Nortec
Systems before the first start-up of the changed system.