Nortec DRAABE Pure Water System User Manual
Page 32
Created: 21.09.2006
Changed: 29.02.2008
Printed: 02.03.2009
page 32 of 59
-
The pure water tank DWD 80 is designed for a maximum pressure of 10 bar (145 psi).
Greater pressures are not permissible!
DWD 18, thread: 3/4”, male
DWD 80, thread: 1”, male
Figure 15: Mounting of storage tank to be mounted on a wall
IMPORTANT:
If a pure water tank is to be mounted downstream from the pressure boost, then it is abso-
lutely necessary to use a DWD 18 or DWD 80.
5.3.5
Pure Water Tank (floor model)
-
If at all possible, the device should be installed in a room to which only a limited cate-
gory of persons is granted access.
-
The location must be selected so that direct sunlight and heat radiation onto the device
is impossible at all times.
-
The pure water tank is designed for a maximum pressure of 3 bar (44 psi). Higher
pressures are not permissible!
5.3.6
Pressure Booster
-
If at all possible, the device should be installed in a room to which only a limited cate-
gory of persons is granted access.
-
The surrounding temperature must lie between +10°C (50°F) and +30°C (86°F)
throughout the year.
-
The location must be selected so that direct sunlight and heat radiation onto the device
is impossible at all times.