Nortec DRAABE Pure Water System User Manual
Page 53
Created: 21.09.2006
Changed: 29.02.2008
Printed: 02.03.2009
page 53 of 59
WM-1000:
volume
1000 litres
dimensions
Ø: 922 mm (36.3 inches), h: 2145 mm (85 inches)
permissible operating pressure
8.6 bar (124 psi)
connection
2
“ (inner)
weight empty
approx. 117kg
approval
GS, CE,
C
CSA
US
8.3
Clear Water System PerPur
PerPur 120 (types CSF2122 or CSF3122):
flow rate
120 kg/h, ± 10%
dimensions
600 x 400 x 400 mm
23.6 x 15.7 x 15.7 inches
weight
approx. 35 kg
operating voltage
120VAC, 60Hz, ± 10%
power consumption
600W
installation category
II
pollution degree
2
application
only in rooms
altitude above sea level
6,670 ft
surrounding temperature
7-35°C (45-95°F)
surrounding humidity
max. 80%, prevent condensation
approval
GS, CE,
C
CSA
US
PerPur 200:
flow rate
200 kg/h, ± 10%
dimensions
600 x 400 x 400 mm
23.6 x 15.7 x 15.7 inches
weight
approx. 40 kg
operating voltage
120VAC, 50-60Hz, ± 10%
power consumption
600W
installation category
II
pollution degree
2
application
only in rooms
altitude above sea level
6,670 ft
surrounding temperature
7-35°C (45-95°F)
surrounding humidity
max. 80%, prevent condensation
approval
GS, CE