beautypg.com

Nortec DRAABE Pure Water System User Manual

Page 16

background image

Created: 21.09.2006
Changed: 29.02.2008
Printed: 02.03.2009

page 16 of 59

3.2.3.3

Explanation of PerPur Display

Two additional functions of the PerPur need to be explained.


The salt consumption optimisation mechanism controlled by a micro processor sees to it
that the water softener is regenerated when a certain customer dependent operating time
has passed. The 5 pole plug 1 (see illustration below) establishes a permanent connection
between the water softener and the pure water system (see section 3.2.2).

The system has a remote fault indicator which is triggered by all malfunctions. If there is a
malfunction, this can be passed via the 2 pole plug 2 to an optical and/or acoustic transmit-
ter. This signal can also be sent to a building services management system.

The remote fault indicator is implemented by a voltage free closer.





plug 1

plug 2




















Figure 7: PerPur Display


Explanation of the LED Displays:

LED Inlet pressure: The water inlet to the Clear Water System is monitored continuously. If

the water supply is disrupted, the pressure switch notices that, the sys-
tem shuts itself down and the red LED lights up.