Nortec DRAABE Pure Water System User Manual
Page 47
Created: 21.09.2006
Changed: 29.02.2008
Printed: 02.03.2009
page 47 of 59
-
Turn off the pure water PerPur unit (1).
-
Block the water supply (2) at the installation rail.
-
Pull the plug-in network part (3) out of the socket.
-
With 2041/2101: Disconnect 5 pole plug (4) at the PerPur unit.
-
Take the hoses with steel jackets (5) away from the water softener (wrench 19).
-
Take away the textile hoses (6) from the water softener and take the device away.
-
Put the new water softener in place, attach hoses, be sure that all seals are present
and in order.
-
Connect plug to the pure water system (PerPur unit).
-
Fill salt container with tablet salt and add 10 litres of water, using a pail.
-
Plug network part into the socket.
-
Open water supply. The pressure indicated by the manometer should rise. Check that
all connections are watertight (visual inspection).
-
Turn on the pure water system (PerPur unit).
The DRAABE Pure Water System (PerPur) turns on automatically in 15 minutes.