The following requirements are placed on the incoming raw water (drinking water):

-

The water must be free of suspended particles which are larger than 5µ.

-

The water must be free of colloids and organic substances.

-

Well water, rain water and fully desalinated water are not acceptable

-

It must meet standards for drinking water (e.g. number of organic materials)

-

The maximum germ content of 1000 germs/ml may not be exceeded.

-

It must have no chemical substances/additives (e.g. chlorine, ozone, disinfectants).

-

No additional devices (e.g. dosing facilities) which change the properties of the in-
coming raw water may be used.

-

Water temperature in the range 6

– 20 °C (43-68 °F).

-

Flow pressure 3

– 4 bar (44-58 psi).


If an osmosis product of some third party is used (i.e. not a DRAABE product), then the fol-
lowing values must be provided continuously by the operator:

-

It must be three stage water preparation

-

Water softening (<0.1 °dH at output)

-

Filtering (aerosol removal filter 5u + activated charcoal filter)

-

Demineralisation via reverse osmosis (inorganic membrane)


-

Water values at output of water preparation

 Water hardness

< 0.1 °dH (< 17 ppm)

 Electric conductance

5-10 µS

 Water temperature

6-25 °C (43-77 °F)

 Flow pressure

2-3 bar (29-44 psi)


-

No use may be made of water tanks with floating controls; rather, closed mem-
branes in stainless steel or plastic for interim storage of the product are to be used
(pressure control).

-

Fittings and pipes must be made of materials which are allowed in the food industry
(plastic, stainless steel). Do not use copper pipes or brass.

-

The pure water must be free of organic substances.