8.2

Water Tanks

8.2.1

Tanks (wall models)


DWD 18:

volume

18 litres

dimensions

Ø 360 mm (14.2 inches)

permissible operating pressure

10 bar (145 psi)

connection

1“ (outer)

weight empty

approx. 6 kg

approval

GS, CE,

C

CSA

US

DWD 80:

volume

80 litres

dimensions

Ø 605 mm (23.5 inches)

permissible operating pressure

10 bar (145 psi)

connection

1“ (outer)

weight empty

approx. 16 kg

approval

GS, CE,

C

CSA

US


8.2.2

Tanks (standing models)


WM-235:

volume

235 litres

dimensions

Ø: 610 mm (24 inches), h: 1088 mm (43 inches)

permissible operating pressure

8.6 bar (124 psi)

connection

1 1/4

“ (inner)

weight empty

approx. 23kg

approval

GS, CE


WM-450:

Volume

450 litres

dimensions

Ø: 610 mm (24 inches), h: 2040 mm (80 inches)

permissible operating pressure

8.6 bar (124 psi)

connection

1 1/4

“ (inner)

weight empty

approx. 43kg

approval

GS, CE


WM-600:

Volume

600 litres

dimensions

Ø: 770 mm (31 inches), h: 1758 mm (70 inches)

permissible operating pressure

8.6 bar (124 psi)

connection

2

“ (inner)

weight empty

approx. 76kg

approval

GS, CE,

C

CSA

US