beautypg.com

4 customer interface, Customer interface – MicroE Mercury II 5000 User Manual

Page 26

background image

Appendix

IM-Mercury_II_5000_Series Rev. 1

Page 25

©2014 MicroE Systems

Mercury II 5000 Series Encoders
Installation Manual and Reference Guide

Sensor mounted to poorly-grounded or non-conducting surface

6.4

Customer Interface

Cable Requirements

Customer cables that interface to Mercury II series encoders must have the following
characteristics:

Twisted pair signals wiring.

Characteristic impedance of 100-120 ohms.

Sufficient wire gauge to meet the minimum voltage requirement at the encoder. For
example: 24AWG gauge wire for a 2m length cable. Recommended cables are 24AWG
gauge wire with 6 twisted pairs.

Single shield cable with a minimum of 90% coverage. Note that a double shielded cable
may be required in high-noise applications.

Signal Wiring for A-quad-B

Each differential signal should be connected to a corresponding twisted pair as follows for the 15-
pin standard male D-sub connector:



Note: The Alarm signal on pin 15 is not differential and is not part of a pair.

Mercury II 5000

Signal

Twisted Pair

Pin

A+

Pair 1

14

A-

6

B+

Pair 2

13

B-

5

Index+

Pair 3

12

Index-

4

Left Limit+

Pair 4

10

Left Limit-

11

Right Limit+

Pair 5

1

Right Limit-

3

+5V

Pair 6

7, 8

GND

2, 9

5 Volts
O Volts