Microcom 814M Operators Manual User Manual
Page 38
34
6.1.2 RS-232
Serial
Interface Signals
Printer serial port signals and status are described in the following table:
6.2 IEEE 1284 Parallel Interface (optional)
6.2.1 Parameters
− Data transmission:
8 bits Parallel
− Synchronization mode: nStrobe signal is provided by exterior
− Handshake mode:
Busy signal
− Signal voltage level: TTL compatible
− Connector:
36 pin – Centronics
6.2.2 Parallel Interface Printer Status (/FAULT pin and PE pin)
PIN NO
Signal
name
Signal
direction
function
1
NO
2
RXD
input
Data input end
3
TXD
output
Data output end
4
DTR
output
Data terminal is ready
5
SG
—
Signal ground
6
DSR
input
Data device is ready
7
RTS
output
Request to send
8
CTS
input
Allow to send
9
FG
—
Frame Ground
Table 6-1 Serial Interface Signals
Status
/FAULT
PE
Normal
high
low
Paper end
low
high
Print head Overheated
low
low
Other errors
low
low
Table 6-2 /FAULT Pin and PE Explanation