3. Modify the Device Setup for On-line Balancing
After you create a new eZ-Balance job, you need to verify that the default setup is valid for your job.
To modify the Acquisition and Input Channels parameters:
a. With the acquisition turned OFF, open the Edit pull-down menu.
b. Select “Configuration.”
c. From the Acquisition Tab’s Hardware pull-down list, select the applicable data acquisition
hardware.
You cannot access the Balance Configuration window while Data Acquisition is active.
The control switch must be set to “OFF.”
Setup Acquisition Tab
Use this panel to select the applicable data acquisition hardware and configure the acquisition parameters
for the eZ-Balance Job. If you make any changes, be sure to click the
The number of balance planes can be equal to or less than the number of response
inputs.