Serial poll status byte, Serial poll bit description – Measurement Computing Serial488/4 User Manual
Page 70

Section 3
Command Descriptions
3.31
Serial Poll Status Byte
The Serial Poll Status byte is sent upon receiving the serial poll command from
the controller. Refer to the SRQ description for details on how the Serial Poll Status
byte is affected. Below is a description of the significance of each bit in
the Serial
Poll Status byte.
Bit Location Value (SRQ Bit Value if set to logic 1)
DIO1(LSB)
1
serial data available on port 1
DIO2
2
serial data available on port 2
DIO3
4
serial data available on port 3
DIO4
8
serial data available on port 4
DIO5
16
Ready for more commands
DIO6
32
Command Error
DIO7
64
Service Request bit
DIO8 (MSB)
128
Memory low warning
Serial Poll Bit Description
DIO1 The DIO1 bit is set by the receipt of serial data on port 1. When enabled by
the M1 command this condition will also generate a Service Request. DIO1 is
cleared when no more data is available to be read on port 1.
DIO2
The DIO2 bit is set by the receipt of serial data on port 2. When enabled by
the M2 command this condition will also generate a Service Request. DIO2 is
cleared when no more data is available to be read on port 2.
DIO3
The DIO3 bit is set by the receipt of serial data on port 3 When enabled by
the M4 command this condition will also generate a Service Request. DIO3 is
cleared when no more data is available to be read on port 3.
DIO4
The DIO4 bit is set by the receipt of serial data on port 4. When enabled by
the M8 command this condition will also generate a Service Request. DIO4 is
cleared when no more data is available to be read on port 4.
DIO5
The DIO5 bit is set after an entire command string has been received and
processed by the Serial488/4. The bit is cleared w hile the Serial488/4 is
processing commands which have been received from the controller. When
used with the M16 command, a Service Request will also be generated w hen