beautypg.com

Bus terminator yn – Measurement Computing Serial488/4 User Manual

Page 68

background image

Section 3

Command Descriptions

3.29

Bus Terminator

Yn

The IEEE 488 bus terminator command selects the characters sent at the end of

status messages returned by the Serial488/4. The terminator may be programmed for
any combination of Carriage Return (CR) and L ine Feed (LF). Y0 sends CR only
and Y1 sends LF only. The Y2 mode, the most commonly accepted terminator, sends
CR-LF. Y3 reverses the sequence to send L F-CR. The factory default setting as set
by the Save Configuration command (S0) is Y2, CR-LF.

Y0

CR only

Y1

LF only

Y2

CR LF

Y3

LF CR

Y?

Return current bus terminator selection.

Example 1: Set terminator to linefeed carriage return using dual primary addressing

mode.

PRINT#1,"CLEAR08"
PRINT#1,"OUTPUT08;Y3X"

select line feed carriage return terminator