Section 1

Introduction

Terminator:
any 8 bit value

Handshaking:
Clear to Send (CTS) / Request to Send (RTS), XON/XOFF, or none

I/O buffers:
56,000 characters - dynamically allocated

Output Voltage:
+ 5 volts minimum (RS-232C); 5 volts typical (RS-422A)

Input Voltage:
+ 3.0 volts minimum: + 15 volts maximum

Connector:
9-pin sub-D male.

IEEE 488

&$87,21

The IEEE 488 terminal must only be used to control a non-
isolated IEEE system. The common mode voltage (cable shell to
earth) must be zero.

Terminal Installation Category:
Standard: Not Applicable.

CE: Category 1.

Implementation:
SH1, AH1, T6, TE8, L4, LE4, SR1, RL0, PP0, DC1, DT0, C0, E1

Terminators:
Selectable CR, LF, LF-CR and CR-LF with EOI

Programmable:
IEEE Terminators, Serial Terminator, EOI, SRQ Mas k, Data Port, Baud Rate,

Word Length, Parity, Stop Bits, Handshake Type, Handshake Control

Connector:
Standard IEEE 488 connector with metric studs

1.3b