beautypg.com

Pinout for personal daq/3000 series modules – Measurement Computing Personal Daq/3000 Series User Manual

Page 26

background image

2-2 Connections & Pinouts

888594

Personal Daq/3000 Series User’s Manual

Pinout for Personal Daq/3000 Series Modules

USB2.0 Edge of Module

Analog Common

Digital Common

DAC0 (Note 1)

Digital

CH 0

DAC1 (Note 1)

Digital

CH 1

DAC2 (Note 1)

Digital

CH 2

DAC3 (Note 1)

Digital

CH 3

Analog Common

Digital

CH 4

Self Calibration

Digital

CH 5

Signal Ground

Digital

CH 6

Digital Common

P

O

R

T

A

Digital

CH 7

TTL Trigger

Digital Common

DPCR (DAC Pacer Clock I/O)

Timer 0 (TMR0)

TB1

APCR (A/D Pacer Clock I/O)

Timer 1 (TMR 1)

TB6

Analog Common

Digital Common

CH 0 / CH 0 HI

Analog

Digital

CH 0

CH 8 / CH 0 LO

Analog

Digital

CH 1

Analog Common

Digital

CH 2

CH 1 / CH 1 HI

Analog

Digital

CH 3

CH 9 / CH 1 LO

Analog

Digital

CH 4

Analog Common

Digital

CH 5

CH 2 / CH 2 HI

Analog

Digital

CH 6

CH 10 / CH 2 LO

Analog

P

O

R

T

B

Digital

CH 7

Analog Common

Digital Common

CH 3 / CH 3 HI

Analog

Counter 0 (CNT0)

TB2

CH 11 / CH 3 LO

Analog

Counter 1 (CNT1)

TB5

Analog Common

Digital Common

CH 4 / CH 4 HI

Analog

Digital

CH 0

CH 12 / CH 4 LO

Analog

Digital

CH 1

Analog Common

Digital

CH 2

CH 5 / CH 5 HI

Analog

Digital

CH 3

CH 13 / CH 5 LO

Analog

Digital

CH 4

Analog Common

Digital

CH 5

CH 6 / CH 6 HI

Analog

Digital

CH 6

CH 14 / CH 6 LO

Analog

P

O

R

T

C

Digital

CH 7

Analog Common

Digital Common

CH 7 / CH 7 HI

Analog

Counter 2 (CNT2)

TB3

CH 15 / CH 7 LO

Analog

Counter 3 (CNT3)

TB4

DSUB25 Edge of Module

Note 1: Personal Daq/3000 includes DAC0 and DAC1; Personal Daq/3001 includes DAC0, DAC1, DAC2,

and DAC3; Personal Daq/3005 has no DACs.

Note 2: Personal Daq/3000 Series devices can measure 16 channels of voltage or 8 channels of temperature.

Temperature measurement requires the use of differential mode.