1. Introduction

OnQ Amplified Combo Modules provide a structured method for distributing
telephone service and RF (cable TV) off air signals throughout a residence.
OnQ Amplified Combo Modules can be mounted in OnQ Service Center
Enclosures and come in several different telecom combinations; an example
(12+8) is shown in Figure 1 to the right.

2. Description

The “video” portion of the module has vertical access “F” style fittings for
connecting incoming and outgoing cables, as well as power.

NOTE: The Video module is a 5-1000 MHz amplifier with typically 4.0 dB
of gain per output port and an insertion loss of typically -1.0 dB in the
5-42 MHz range.

The “telecom” portion provides an RJ45 modular jack or 110 punchdown
block for connecting and distributing incoming telephone service to room
locations. Also provided on some configurations is a modular jack labeled
“Security” for interfacing to security systems.

NOTE: The OnQ Combo Module has a vertical dimension of 5 inches.

A total of 7 inches of enclosure space is required for coax cabling.

3. Installation

A. Mounting in Enclosure (refer to Figure 2).

1)

Align tabs on the module with slots on rail enclosure.

2)

Insert tabs by angling module away from the back of the
enclosure.

3)

Rotate the module and insert fasteners on module into
corresponding holes on rail of enclosure. (Plunger must be in
a pulled position for fastener to engage hole.).

4)

Push plunger in to lock module in place. Pull on module to
ensure module is locked properly in place.

B. Service Connection - Video Portion (refer to Figure 3).

1)

Identify incoming service cable(s) and route to “Cable In” fit-
ting(s) on module.

2)

Attach an RG-6 “F” connector to the cable. Connect to fitting
on module and finger-tighten.

C. Service Connection - Telecom Portion

1)

Identify incoming service cable and route to RJ45 jack or 110
punchdown block labeled “Line In”.

2)

Trim the cable to allow at least three (3) inches of excess
cable.

3)

Terminate the cable with an EZ-RJ45 modular plug
(P/N 364554-01, not included) if applicable. Be sure to use
proper terminating tool (P/N 364555-01 per IS-0177). If using
110 punchdown block, insert leads and terminate using
punchdown tool (P/N 363293-01, not included).