863 SERIES FLOOR BOX APPLICATIONS:
5. Place the gasket support plate over the receptacle and
attach it with supplied #6 round head screw (duplex style
receptacle only).
6. Pull data cables through the box, and attach the cables to
supplied connectors. Insert the connectors with cable into
the supplied bezel. - Snap the bezel into the round box.
(Note: Notches in the bezel have to face out – see figure 1).
7. Place the gasket over the support
plate, and slide the cover with four
attached #8/32 studs into the
round box.
Connectors
Notches
8. Attach the cover to the box using
supplied #8/32 hex nuts, tighten
the hex nuts until the gasket is
compressed approximately 50%
(1/16 in.) [1.6mm] of the thickness
or more.
9. Attach assembled unit to the floor
using supplied #5 - 3/4" [19mm]
wood screws – Drill Pilot Hole –
1/16" [1.6mm] Soft Wood, 5/16"
[7.9mm] Hard Wood.
Stud