WARRANTY INFORMATION
Manufacturer warranties its products to be free of
defects in materials and workmanship for a period
of five (5) years. There are no obligations or liabilities
on the part of manufacturer for consequential
damages arising out of, or in connection with, the
use or performance of this product or other indirect
damages with respect to loss of property, revenue or
profit, or cost of removal, installation or reinstallation.
Please
Recycle
06145r3 9/2007
Legrand Customers contact:
Vantage Customers contact:
1061 South 800 East
Orem, UT 84097
Phone: 800.555.9891
www.vantagecontrols.com
301 Fulling Mill Road Suite G
Middletown, PA 17057
Phone: 800.321.2343
www.legrand.us/onq
CLEANING & MAINTENANCE OPERATIONS
Clean only using a cloth dampened with water and a little
mild detergent. Use of solvents or hydrocarbon-based
cleaners may cause permanent damage.
Replacing Lamps
When a lamp must be replaced, disconnect power.
Power Fail Memory
After a power failure, all wireless devices automatically
return to the state that they were in immediately prior
to loss of power. All configuration and scene control
information is preserved.
TROUBLESHOOTING FOR WIRELESS
During Set House ID, the LED is not flashing on some
wireless Miro devices.
• If LED is solid green before initiating house ID binding:
The device already has another house ID. Reset it to the
factory default so that it can be bound to the desired
house ID. Resetting to factory defaults is described in
the “I need to start over” issue.
• If LED is solid yellow after initiating house ID binding:
The device may be out of range of the initiating device.
Add a MRR2 Miro Wireless Repeater to boost signal
range.
I made a configuration mistake. I need to start over.
You can reset any Miro wireless device to factory default
setting by pressing and holding until the LED changes
to solid yellow (approximately 10 seconds). During the
process, the LED flashes yellow and when complete,
it changes to solid yellow. The device can then be
reconfigured, exactly like any new device (see the Set
House ID section).
The Dimmer does not work and the status LED is
flashing red.
• at 1Hz (5 times in 5 seconds):
The dimmer has detected an unsuitable load or load
below the minimum rated load for the applied voltage.
To clear the fault condition, tap and wait for the
LED to turn green. Disconnect power, check the load,
restore power and try again.
FCC NOTICE
FCC ID: Q4BMR2K
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this
device must accept any interference received, including
interference that may cause undesired operation.
Caution: Any changes or modifications to this device
not explicitly approved by manufacturer could void your