Is-0421 rev. o – Legrand AU5008-XX User Manual
Page 3
301 Fulling Mill Road, Suite G
Middletown, PA 17057
Phone (800) 321-2343 / Fax (717) 702-2546
www.onqlegrand.com
Page 3 of 4
INSTRUCTION/INSTALLATION SHEET
lyriQ™ Studio Local Source Input
IS-0421 REV. O
©Copyright 2008 by On-Q/Legrand All Rights
Reserved
.
Input) out of the single gang box and terminate it with an RJ45 plug and snap it into the RJ45 jack
labeled “OUTPUT” on the rear (see Figure 2).
3. Insure the jumper on the rear is set to support Keypads (bridging pins 1 and 2) or moved to the Knob
position (bridging pins 2 and 3) if using knob-style lyriQ™ volume controls.
NOTE: This jumper setting will have an impact on how the lyriQ™ Local Source Input operates. In Knob
mode, it operates similar to the standard Local Source Input (P/N F7417). When an active local audio
source is sensed, it switches to that source for the local lyriQ™ Knob Volume Control, and when that
source goes inactive, it switches back to the main source (after the adjustable delay). When in Keypad
mode, operation depends upon whether it is attached to a Classic lyriQ™ Keypad or a lyriQ™ Studio
Keypad. If attached to a Classic lyriQ™ Keypad, it acts the same as if in Knob mode. If it is attached to a
lyriQ™ Studio Keypad, it now responds to a “switch to Studio Local Source #1 or #2” button push on the
Studio Keypad for support of selectable local audio source inputs.
4. Mounting: Use the included screws to install the lyriQ™ Studio Local Source Input into the single
gang box and use a standard Decorator style or Studio style wall plates.
NOTE: Insure there is not excessive strain on the Category 5 cable when mounting the lyriQ™ Studio
Local Source Input.
Figure 3