INSTRUCTION/INSTALLATION SHEET
lyriQ™ Studio Local Source Input

IS-0421 REV. O

©Copyright 2008 by On-Q/Legrand All Rights

Reserved

.

delay for switching back to the main audio source after the local audio source is no longer present.

NOTE: Clockwise rotation increases sensitivity and time delay, while Counter Clockwise rotation
decreases sensitivity and time delay.

There is a jumper on the rear that determines whether the lyriQ™ Studio Local Source Input works in Knob
mode or Keypad mode (see NOTE after Installation step B3).

NOTE: The lyriQ™ Studio Local Source Input, like other On-Q/Legrand lyriQ™ Audio system
components, is powered by the On-Q/Legrand lyriQ™
Audio Distribution Module.

3. Installation


Installation of the On-Q lyriQ™ Studio Local Source Input is best accomplished in two steps during new
construction, at “Rough-in” before the drywall is installed, and at “Trim-out” after the drywall is installed and
painted.

NOTE: The On-Q/Legrand lyriQ™
Studio Local Source Input is typically mounted at electrical outlet
height. Measure the height of the nearest box on the same wall that the lyriQ™
Studio Local Source Input
will be installed and place the electrical back box at the same height. Position the cabling to maintain
separation of any low voltage cable such as Category 5 from AC power wiring. Special applications, such
as audio from a TV, entertainment center, or a computer, may require different heights including those
above the chair rail, such as in the kitchen.

A. “Rough-in” steps:

1. Run Category 5 cable from the lyriQ™ Audio Distribution Module located in the Enclosure to the single

gang box at the location that will contain the lyriQ™ Studio Local Source Input. Also run Category 5
cable from the single gang box that will contain the lyriQ™ Studio Local Source Input to the volume
control location (or to the second lyriQ™ Studio Local Source Input and then to the volume control
location).

NOTE: If optional 16/4 speaker cable is run with the Category 5 cable for potential upgrade to high
performance keypads in the future (see Figure 3 and 4
), it can be run directly from the enclosure to the
volume control.

B. “Trim-out”

steps:


NOTE: Always follow TIA-570-B and T568A wiring standards for installing and terminating Category 5
cable. Failure to follow the correct wiring standard could result in damaged equipment and/or electrical
interference issues.
NOTE: Maintain a minimum 12” separation between Category 5 cable and any 120VAC cabling.

1. At the intended Studio Local Source Input location, pull the prewired Category 5 cable from the

lyriQ™ Audio Distribution Module out of the single gang box and terminate it with an RJ45 plug and
snap it into the RJ45 jack labeled “INPUT” on the rear (see Figure 2).


2. Pull the prewired Category 5 cable from the lyriQ™ Volume Control (or next Studio Local Source