Legrand TITAN Series v.2 User Manual
Page 3
MULTI GANG INSTALLATION INSTRUCTIONS
FINS ARE NOT REMOVED
NOTE: A 3-gang Installation of Narrow Dimmers is shown and described
below. Any Combination of Wide and Narrow Dimmers will gang the same way.
1. Select the correct box size from Table 6.
Table 6 – Wall-box Gang Requirements – FINS are NOT REMOVED
3. Connect the dimmer as shown in the wiring diagram using the appropriate
sized wire connectors.
4. With the word “TOP” up, install dimmer in the wall box using mounting
screws provided (leave mounting screws “finger tight” at this point).
5. Attach the Couplers between the Dimmers with the screws that were
removed in step 2.
Remove this screw to remove End Cap
End Cap
Remove this screw to remove End Cap
*Wall Box Requirements for Ganging an Even Number of Narrow Dimmers.
4+1 set up shown below:
Chase nipple
4-gang
wall box
1-gang
wall box
2.712
Narrow Dimmers
0
1
2
3
4
5
6
0
0
1
1+1*
4
4+1*
7
7+1*
1
1
3
5
6
8
9
11
2
4
5
7
8
10
11
13
3
6
8
9
11
12
14
15
4
9
10
12
13
15
16
-
5
11
13
14
16
–
–
-
6
14
15
–
–
–
–
W
id
e
D
im
m
er
s
MULTIPLE GANGING OF DIMMERS
Any combination of dimmer models may be ganged together. Using a vise or heavy-duty pliers, remove the fins on either or both sides of the heat sink, as
necessary. Dimmers can be ganged without removing fins by proper selection and placement of outlet boxes (see Table 6 and Table 7). When Dimmers are ganged,
De-rate the maximum load according to the following De-Rating Table 5:
Table 5 – Derating for Multi-Gang Installations
2. Remove the End Cap between adjacent dimmers (2 screws for each End
Cap). Keep these screws as they will be needed at step #5.
NOTE: The End Cap that is not between dimmers does not get removed.
Fins are NOT Removed
Fins are Removed
Dimmer
1-Gang
2-Gang
3- or more Gang
2-Gang
3- or more Gang
Catalog #
Installation
Installation
Installation
Installation
Installation
CD700
700W
700W
700W
700W
700W
CDLV700
700VA
700VA
700VA
700VA
700VA
CD703P
700W
700W
700W
700W
700W
CDLV703P
700VA
700VA
700VA
700VA
700VA
CD1100
1100W
1100W
1000W
1000W
900W
Narrow
CDLV1100
1100VA
1100VA
1000VA
1000VA
850VA
Dimmers
CD1103P
1100W
1100W
1000W
1000W
950W
CDLV1103P
1100VA
1100VA
1000VA
1000VA
850VA
CDFB5
5A
5A
5A
5A
5A
CDFB8
8A
8A
8A
7.7A
6.3A
CDFB53P
5A
5A
5A
5A
5A
CDFB83P
8A
8A
8A
7.7A
6.3A
CDSC6
6A
6A
6A
6A
6A
CDDH16
1.6A
1.6A
1.6A
1.6A
1.6A
CD3FB16
16A
16A
16A
16A
16A
CD3FB163P
16A
16A
16A
16A
16A
CD3FB10-277
10A
10A
10A
10A
10A
CD3FB103P-277
10A
10A
10A
10A
10A
CD1600
1600W
1600W
1600W
1600W
1550W
CDLV1600
1600VA
1600VA
1600VA
1600VA
1550VA
CD1603P
1600W
1600W
1600W
1600W
1550W
CDLV1603P
1600VA
1600VA
1600VA
1600VA
1550VA
CD2000
2000W
2000W
2000W
NO FINS TO REMOVE
CD2003P
2000W
2000W
2000W
Wide
CDFB10
10A
10A
10A
10A
10A
Dimmers
CDFB16
16A
16A
16A
NO FINS TO REMOVE
CDFB7-277
7A
7A
7A
7A
7A
CDFB10-277
10A
10A
10A
10A
10A
CDSC12
12A
12A
12A
12A
12A
CDFB103P
10A
10A
10A
10A
10A
CDFB163P
16A
16A
16A
NO FINS TO REMOVE
CDFB73P-277
7A
7A
7A
7A
7A
CDFB103P-277
10A
10A
10A
10A
10A
Couplers
6. Tighten the mounting screws, insert the label, attach the wall plate, and
restore power to the circuit.
7. Calibrate the Dimmer if necessary – Refer to Single Gang Installation
Instructions, step #7.
f. Fluorescent Dimmers “CD3FB” Series: No adjustments are required.
The minimum light level is calibrated at the factory and does not
normally require adjustment. If the lamps drop out or flicker at the
minimum dimming level, there may be an installation error.
NOTE: To ensure full lamp life and proper dimming performance, it is rec-
ommended to “season” fluorescent lamps prior to dimming. This is accom-
plished by operating the lamps at maximum light levels for up to 100 hours.
Refer to individual lamp manufacturer for recommended seasoning times.