SINGLE GANG INSTALLATION INSTRUCTIONS

1. Disconnect power to circuit by removing fuse or turn

circuit breakers OFF before installing.

2. For existing installations: Remove wall plate and

switch mounting screws, pull existing switch from wall

box. For new installations: Install a 1-gang wall-box.

3. Disconnect existing switch from circuit. 3-way

installation: Identify the “COMMON” wire (wire

connected to the terminal marked common or odd

colored terminal). For “new” installation identify wire

connected to power source or to the load.

4. Connect dimmer as shown in the wire diagram with

appropriate sized wire connectors (see Table 4).

5. Install dimmer in wall box, with the word “TOP” up, using mounting screws provided.
6. Insert the label, attach the wall plate and restore power to the circuit.
7. Dimmer Set-up Adjustments:

a. Incandescent Dimmer: The Full ON voltage can be reduced to save energy

by reducing the Full ON light level. To change the Full ON light level, slide

the dimmer knob up to its full brightness. DISCONNECT POWER FROM

CIRCUIT, and remove the wall plate. Use a small insulated, screwdriver to

adjust the trim potentiometer. Turn down to decrease the Full ON light level.

b. Magnetic Low Voltage Dimmer: The minimum light level may need

adjustment for variations in low voltage transformers. To change the

minimum light level, slide the dimmer knob down to the lowest

brightness. DISCONNECT POWER FROM CIRCUIT, and remove the wall

plate. Use a small insulated, screwdriver to adjust the trim potentio-

meter. Turn down to decrease the minimum light level.

c. Fan Speed Controls: The minimum fan speed level may need adjustment

for variations in fans. To change the minimum fan speed, slide the knob

down to the lowest level. DISCONNECT POWER FROM CIRCUIT, and

remove the wall plate. Use a small insulated, screwdriver to adjust the

trim potentiometer. Turn down to decrease the fan speed. Make certain

that the fan does not “stall” in any of the ON positions as overheating of

the fan may occur. DO NOT USE THE FAN PULL CHAIN TO CHANGE

SPEEDS AFTER THIS CONTROL IS INSTALLED. THE FAN PULL CHAIN

NEEDS TO REMAIN AT THE MAXIMUM SPEED.

d. Dehummer Fan Speed Controls: No adjustments required. Make certain

that the fan does not “stall” in any of the ON positions as overheating of

the fan may occur. DO NOT USE THE FAN PULL CHAIN TO CHANGE

SPEEDS AFTER THIS CONTROL IS INSTALLED. THE FAN PULL CHAIN

NEEDS TO REMAIN AT THE MAXIMUM SPEED.

e. Fluorescent Dimmers “CDFB”

Series: The minimum light level

may need adjustment for variations

in ballasts. To change the minimum

light level, slide the dimmer knob

down to the lowest brightness.

DISCONNECT POWER FROM CIR-

CUIT, and remove the wall plate.

Use a small insulated, screwdriver

to adjust the trim potentiometer.

Turn up to increase the minimum

light level.

WIRING DIAGRAMS

Table 4

WIRING INFORMATION

IMPORTANT NOTES Read the following before installation:
• Requirements for wire strip length and wire connections.
Table 3 - WIRE NUT USAGE CHART

• Use a separate neutral wire for each phase of a multiphase system

containing a dimmer, and for high power single phase applications where

flickering is present.

• All dimmers can be damaged by improper wiring. Check for short circuits

prior to installing the dimmer.

Procedure for short circuit check:

a. Disconnect power to the circuit by removing fuse or turning circuit

breakers OFF.

b. Install a switch instead of the dimmer. Turn the switch to the “on” position.

c. Turn power ON. If the circuit breaker trips, a short is present. If the light

fails to turn ON and OFF with the switch, the wiring may be incorrect.

d. Correct wiring, if necessary and retest.

e. Install the dimmer only after the light operates properly with the switch.

• Protect from dirt and dust. The dimmer can be damaged from contamin-

ates encountered during the construction process. If lighting is required

prior to the construction process completion, then a switch should be

temporarily installed in place of the dimmer. The dimmer should not be

installed until the construction process is complete.

• Any dimmer damaged by improper installation is not covered under warranty.

• It is normal for the dimmer to feel warm during operation.

• Cleaning Instructions: Wipe dimmer with a damp, clean cloth.

DO NOT clean the dimmer with chemicals or cleaning solutions.

Dimmer Catalog #

Diagram #

CD700, CD1100, CDLV700, CDLV1100, CD1600, CDLV1600,

CD2000, CDFB5, CDFB8, CDFB10, CDFB16, CDFB7-277,

1

CDFB10-277, CDDH16, CDSC6, CDSC12
For Single Pole Installation of: CD703P, CD1103P, CDLV703P,

CDLV1103P, CD1603P, CDLV1603P, CD2003P, CDFB53P, CDFB83P,

2

CDFB103P, CDFB163P, CDFB73P-277, CDFB103P-277
For 3-Way Installation of: CD703P, CD1103P, CDLV703P,

CDLV1103P, CD1603P, CDLV1603P, CD2003P, CDFB53P,

3

CDFB83P, CDFB103P, CDFB163P, CDFB73P-277, CDFB103P-277
For 4-Way Installation of: CD703P, CD1103P, CDLV703P,

CDLV1103P, CD1603P, CDLV1603P, CD2003P, CDFB53P, CDFB83P,

4

CDFB103P, CDFB163P, CDFB73P-277, CDFB103P-277

CD3FB16, CD3FB10-277

5

For Single Pole Installation of: CD3FB163P, CD3FB103P-277

6

For 3-Way Installation of: CD3FB163P, CD3FB103P-277

7

Wire Combinations

Strip Lengths

Color

1#14 & 1#16; 1#14 & 2#18; 2,3#16;

1/2" Except 9/16"

Orange

1#16 & 1-3#18; 3-5#18; 2#18

For #16 & #18 AWG

1#10 & 1#14; 1#12 & 1#14 2, 3#14;

1/2" Except 5/8"

Yellow

2#14 & 1,2#16; 2#14 & 2,3#18;

For #16 AWG

1#14 & 1-4#16; 1#14 & 1-4#18
1#10 & 1,2#12; 1#10 & 1-3#14; 2,3#12;

7/16" Except 1/2"

Red

1#12 & 1-3#14; 1#12 & 3#16; 3,4#14

For #16

1#14 & 1,2#16; 1#14 & 1,2#16;

7/16" For #14 & #16

Ivory

2,3#16; 2-5#18

1/2" For #18

Use Only Copper Wire With This Device.

DIAGRAM 1 (Single-Pole Wiring)

DIAGRAM 2 (Single-Pole Wiring Using 3-Way Preset Dimmer)

DIAGRAM 3 (3-Way Wiring)

DIAGRAM 4 (4-Way Wiring)

DIAGRAM 5 (Single-Pole Wiring)

DIAGRAM 6 (Single-Pole Wiring Using 3-Way Preset Dimmer)

DIAGRAM 7 (3-Way Wiring)

CAUTION: To be installed by a certified electrician or other qualified person.
WARNING: To prevent severe shock or electrocution, always turn power

OFF at the service panel before installing this dimmer, working on the

circuit, or changing a lamp.

Knob

Trim

Potentiometer
NOTE: Never

adjust trim

potentiometer

when circuit

is live.