beautypg.com

Legrand 5406BK User Manual

Legrand Hardware

background image

Black Wire

Fil noir

Alambre negro

Outer jacket removed

Gaine extérieure retirée

Forro exterior removido

Strip

Dénuder
Desforre

Cut

Couper

Corte

Strip

Dénuder
Desforre

(HOT, CHAUD, FASE)

(NEUTRAL, NEUTRE, NEUTRO)

(SMOOTH, LISSE, LISO)

(RIBBED, NERVURÉ, ESTRIADOS)

2.62"

(6.65 cm)

.12"

(.30 cm)

.75"

(1.9 cm)

.75"

(1.9 cm)

INSTALLATION INSTRUCTIONS

Feed-thru Cord Switch 5406

READ AND SAVE THESE INSTRUCTIONS!

Suitable for:

16/2 SPT-2, 18/2 SPT-2, 18/2 SPT-1,

18/2 SVT (round flexible cord), and cords up to 9/32"

maximum diameter.
Important: Turn circuit breaker OFF or remove fuse(s)
and test that power is off.

Important: Use copper wire only. Do not tin conductors.

1. Cut and strip black wire (round SVT cord) or smooth

wire (flat SPT cord) as shown below. Do not cut insula-

tion from white wire (round cord) or ribbed wire (flat

cord). Ensure that white wire (round cord) or ribbed wire

(flat cord) is routed through bottom channel inside switch

cover. (See Figure 1, Figure 2)

2. Loosen the strain relief clamps and insert wires through

clamps.

3. Twist strands together and wrap 3/4 turn clockwise

under the heads of the screws and tighten securely.

No loose strands. (See Figure 3)

4. Tighten strain relief clamps securely.
5. For large cords, carefully cut out the holes at the ends

of the housing. (See Figure 3)

6. Ensure that white wire (round cord) or ribbed wire

(flat cord) is routed through bottom channel inside

switch cover. (See Figure 3)

7. Assemble the cover, and tighten screws.
Must be installed and used in accordance with
electrical codes.

Stripping Diagram – Round Flexible Cord, SVT
Schéma de dénudage – Cordon souple rond (SVT)
Diagrama de Pelado – Cordón redondo flexible, SVT

Stripping Diagram – Flat Flexible Cord, SPT
Schéma de dénudage – Cordon souple plat (SPT)
Diagrama de Pelado – Cordón plano flexible, SPT

Wiring Diagram – Cord Placement

Schéma de câblage – Emplacement
du cordon

Diagrama de cableado – Ubicación
del cordón

CAUTION: To reduce the risk of fire or electric shock,

do not strip wires – Cut off end of cord cleanly

Figure 1/Figure 1/Figura 1

Figure 3/Figure 3/Figura 3

Figure 2/Figure 2/Figura 2

Strain Relief Clamp

Collier de réduction
de tension

Abrazadera de alivio de
esfuerzo mecánico

Strain Relief Clamp

Collier de réduction de tension

Abrazadera de alivio de
esfuerzo mecánico

Neutral Wire

Fil neutre

Conductor neutro

Cut Off Section

Section défonçable

Sectión p/cortar

340883_FeedThruCord InstSht:340883_IS

6/29/09

4:38 PM

Page 1

This manual is related to the following products: