CABLE

CATEGORY/

O.D.

40% FILL 1/2

TYPE

DESIGNATION

Inches

[mm]

COMPARTMENT

UNSHIELDED

4-pair, 24 AWG Cat 3

0.190

[4.8]

68

TWISTED PAIR

4-pair, 24 AWG Cat 5e

0.210

[5.3]

56

4-pair, 24 AWG Cat 6

0.250

[6.3]

40

4-pair, 24 AWG Cat 6a*

0.335

[8.5]

22

25-pair, 24 AWG

0.360

[9.1]

18

COAXIAL

RG6/U

0.270

[6.9]

34

FIBER

ZipCord

0.118 x 0.236

[3 x 6]

70

Round 4 Strand Fiber

0.187

[4.8]

71

Round 6 Strand Fiber

0.256

[6.5]

38

* Category 6 Augmented cable for 10 gigabit ethernet – max allowed cable diameter per Addendum 11 to

ANSI/TIA-568-B.2.

ALDS4000 Raceway Wire Fill Capacities for Communication

WIRE SIZE

O.D.

ALDS4011

ALDS4015

ALDS4017

ALDS4018

THHN

Inches

[mm]

40%

60%

40%** 60%**

40%**

60%**

40%**

60%**

THHN

14

0.111

[2.8]

122

182

49

73

75

112

133

199

12

0.130

[3.3]

89

133

35

53

54

82

97

145

10

0.164

[4.2]

56

84

22

34

34

51

61

92

8

0.216

[5.5]

32

48

13

19

20

30

35

53

6

0.254

[6.5]

23

35

9

14

14

21

25

38

UTP

2-pair, 24 AWG

0.150

[4.8]

67

100

27

40

41

61

73

109

4-pair, 24 AWG Cat 3

0.190

[4.8]

42

62

17

25

25

38

45

68

4-pair, 24 AWG Cat 5e

0.210

[5.3]

34

51

14

20

21

31

37

56

4-pair, 24 AWG Cat 6

0.250

[6.3]

24

36

10

14

15

22

26

39

4-pair, 24 AWG Cat 6a*

0.354

[9.0]

13

20

5

8

8

12

15

22

25-pair, 24 AWG

0.410

[10.4]

12

17

5

7

7

11

13

10

Coaxial RG6/U

0.270

[6.9]

21

31

8

12

13

19

22

24

Fiber

ZipCord

0.118 x 0.236 [3 x 6]

42

64

17

25

26

39

46

69

Round 4 Strand Fiber

0.187

[4.8]

43

64

17

26

26

40

47

70

Round 6 Strand Fiber

0.256

[6.5]

23

34

9

14

14

21

25

38

* Entrance end fitting fill rate is calculated using backfeed capability and radius inserts. Inserts are removable and fitting can

obtain maximum raceway fill from utilizing end fitting knockouts and removing radius control inserts.

**Calculated using radius control inserts. Inserts are factory installed and may be removed in order to obtain full raceway

capacity if radius control is not required.

ALDS4000 Raceway Fittings Wire Fill Capacity Chart

NOTE: For additional information, refer to the Technical Section of the current version of ED439 (Wiremold Buyer’s Guide).

NUMBER OF CONDUCTORS (40% FILL)

WIRE SIZE

O.D.

w/DUPLEX

w/SURGE

LARGE SINGLE

THHN/THWN

Inches

[mm]

WITHOUT

RECT. DEVICE

GFCI DEVICE

RECEPTACLE

DEVICES

1.59in.

2

[1025mm

2

]

2.30in.

2

[1485mm

2

]

3.00in.

2

[1935mm

2

]

14 AWG

0.111

[2.8]

200

134

105

76

12 AWG

0.130

[3.3]

146

98

77

56

10 AWG

0.164

[4.2]

92

62

48

35

8 AWG

0.216

[5.5]

53

36

28

20

6 AWG

0.254

[6.5]

38

26

20

15

ALDS4000 Raceway Wire Fill Capacities for Power