Figure 3 – Legrand WKD ProSeries Underfloor Duct Trim Flange User Manual
Page 2

The Wiremold Company
U.S. and International:
60 Woodlawn Street • West Hartford, CT 06110
1-800-621-0049 • FAX 860-232-2062 • Outside U.S.: 860-233-6251
Canada:
850 Gartshore Street • Fergus, Ontario N1M 2W8
1-800-741-7957 • FAX 519-843-5980
1 002 598 0702
© Copyright 2002 The Wiremold Company All Rights Reserved
S125-837PCC Assembly with 828PR and 829PSTC:
Step 4. Important: Tighten bonding screw in base of preset.
Step 5. Using hardware bag 97650A secure link straps
to posts in preset. Position straps in outer presets
A. Pull wires to preset and leave slack.
for three-gang flange. None are used in center
B. Use Cat. No. 427 Fiber Optic Loop Kit
preset. Install two flathead screws in opposite
if fiber optic cable is being installed.
corners to attach flange to link straps. Two lengths
of screws are provided to accommodate variations
in concrete pour depth (see Figure 3).
Step 6. Make splices in preset and pull wire through connector
to final termination.
A. Wire UL Listed device or power/communication
devices and attach to trim flange.
B. Attach cover plates and complete installation
as shown.
C. For tile floors, apply a bead of caulking along
bottom perimeter of trim flange.
Double Duplex Cover,
Membrane and
Receptacles Included
with Assembly – Orient
receptacles with Neutral
Sides Facing Each Other
829PSTC Communication
Cover, or Other As Required
Pro Series Preset or Afterset Insert
Link Strap (Four Required)
828PR Duplex Cover,
or Other As Required
Figure 3