Legrand WKD Pro Series Round Flush Cover Plates User Manual
Page 3
COMMUNICATIONS COVER:
(2" [51mm] min. preset depth)
1. Wire and snap appropriate communication jacks into adapters as
shown above.
2. Insert blanking plugs or neoprene foam blocks in unused
communication ports.
3. Insert jacks through underside of trim flange and snap into place.
4. Attach trim flange with jacks to the preset adapter plate using (4)
#6-32 flat head screws.
5. Align gasket over devices and press bead into trim flange channel.
6. Install slide cover with (2) #6-32 pan head cover screws.
CAUTION:
Gasket must be in place to provide scrub water seal.
CAUTION:
Do not over tighten cover screws.
#6-32 Pan
Head Screw
Slide Cover
Gasket
Trim Flange
#6-32 Flat
Head Screw
PARTITION FEED COVER:
(1" [25mm] min. preset depth)
1. Attach conduit flange to the preset adapter plate using (4)
#6-32 pan head screws.
2. Remove screw plugs and install flexible conduit fittings with conduit.
NOTE:
Keep screw plugs for future abandonment.
#6-32 Pan
Head Screw
Conduit
Flange
2" TRADE SIZE PARTITION FEED COVER:
(1" [25mm] min. preset depth)
1. Attach conduit flange to the preset adapter plate using
(4) #6-32 pan head screws.
2. Remove screw plugs and install conduit fittings with conduit.
NOTE:
Keep screw plugs for future abandonment.
Conduit
Flange
#6-32 Pan
Head Screw