Activate Cat 5e Jack

(Supplied)

CAUTION: Empty communication ports must be closed off

with foam blocks, or TracJack blanks to maintain
Fire Classification.

Foam Block

(Supplied)

Comm Jack

(Sold Separately)

Pass & Seymour

Keystone Bezel

Activate Bezel

(Supplied)

Pass & Seymour ACTIVATE Bezel and Communication Jack
(Supplied with AMD8ATC & AMD8CTC Units).

Ortronics Series II Bezel & Communication Jacks (Series II Bezel
Included with AMD8ARTTC and AMD8CRTTC, Series II Modular
Inserts Sold Separately).

Ortronics TracJack Bezel & Communication Jack (Bezel Supplied
with AMD8ARTTC and AMD8CRTTC TracJacks Sold Separately).

Ortronics TracJack

(Not Supplied)

Ortronics TracJack Bezel

(Supplied)

Step 6 Wire and snap communication jacks in adapters

as shown.

Step 7

Insert blanking plugs, plates or neoprene foam
blocks in unused communication ports.

NOTE: In order to maintain UL Fire Classification, all communication modules and/or blank inserts (factory or customer supplied) must be UL

Listed Communication Circuit Accessories. Modules and/or blank inserts must have a secure fit with the supplied communication
brackets with no visual openings between communication modules and communication brackets. All unused openings must be
sealed with the appropriate blanking plugs. If cables are to pass through communication openings, any opening between the cable
and the insert or bracket must be sealed with the supplied foam plug.

Ortronics Series II Jack

(Not Supplied)

Ortronics Series II

Bezel (Supplied)

TracJack Blank

(Supplied)

Ortronics TracJack

Bezel