Sealing the dies
Vectris Model Separator is applied in two coats. Apply the first layer slightly more generously than the second one and
make sure to fully cover all areas of the die. Watch out for sharp edges in particular. Allow the first layer to react for
3 minutes. Subsequently, apply the second layer of Vectris Model Separator in a thin coating, invert the die and allow to
dry for 3 minutes.
Apply a generous coating of Vectris Model Separator and allow it to dry for 3 minutes.
Apply the second layer of Vectris Model Separator in a thin coating, invert the die and allow it
to dry for 3 minutes.
Version A
Flat occlusal preparation
Version B
Deep occlusal preparation
Preparing the die for the vacuum-forming process
Before removing the Vectris Single from the packaging, adjust the height of the model carrier in the vacuum former so that
the distance between the model and the upper rim of the container is 2 to max. 3 cm. If necessary, further adjust the
height by means of the spacer rings. Finally, check the position of the membrane.
Check the height of the model on the model carrier and, if necessary, adjust by means of the spacer rings.
Version A
Flat occlusal preparation
Version B
Deep occlusal preparation
2– max. 3 cm
2– max. 3 cm