32

Sealing the dies

Vectris Model Separator is applied in two coats. Apply the first layer slightly more generously than the second one and

make sure to fully cover all areas of the die. Watch out for sharp edges in particular. Allow the first layer to react for

3 minutes. Subsequently, apply the second layer of Vectris Model Separator in a thin coating, invert the die and allow to

dry for 3 minutes.

Apply a generous coating of Vectris Model Separator and allow it to dry for 3 minutes.

Apply the second layer of Vectris Model Separator in a thin coating, invert the die and allow it

to dry for 3 minutes.

Version A

Flat occlusal preparation

Version B

Deep occlusal preparation

Preparing the die for the vacuum-forming process

Before removing the Vectris Single from the packaging, adjust the height of the model carrier in the vacuum former so that

the distance between the model and the upper rim of the container is 2 to max. 3 cm. If necessary, further adjust the

height by means of the spacer rings. Finally, check the position of the membrane.

Check the height of the model on the model carrier and, if necessary, adjust by means of the spacer rings.

Version A

Flat occlusal preparation

Version B

Deep occlusal preparation

2– max. 3 cm

2– max. 3 cm