Ivoclar Vivadent Vectris User Manual
Page 20

20
Duplicate die/model
✔
*
✔
*
✔
✔
*
✔
Transil matrix
✔
✔
*
✔
✔
✔
Framework thickness
at least
at least
at least
at least
at least
Vectris abutment
0.3–0.4 mm
0.3–0.4 mm
0.3–0.4 mm
0.3–0.4 mm
0.3–0.4 mm
Joint face of the connector
–
–
at least
at least
at least
3 x 3 mm
3 x 3 mm
3 x 3 mm
Thickness of pontic/abutment
–
–
at least
at least
at least
contact layer
0.3 mm
0.3 mm
0.3 mm
Length of the pontic/abutment
–
–
at least
at least
at least
contact layer
3 mm
3 mm
3 mm
Long Pontic ribbon
–
–
1 x
1 x
1 x
Medium-sized Pontic ribbon
–
–
1 x
1 x
1 x
Short Pontic ribbon
–
✔
*
2–3 x
3–5 x
3–5 x
Grit size of Al
2
O
3
jet medium
80–100 µm
80–100 µm
80–100 µm
80–100 µm
80–100 µm
Pressure
1 bar (14.5 psi)
1 bar (14.5 psi) 1 bar (14.5 psi)
1 bar (14.5 psi)
1 bar (14.5 psi)
Cleaning with air or steam
Minimum reaction time
1 min.
1 min.
1 min.
1 min.
1 min.
of the wetting liquid
Anterior
crowns
Posterior
crowns
Anterior
bridges
Posterior
bridges
Inlay-retained
bridges
It is essential to observe the following points when designing Vectris frameworks:
1. Designing the silicone matrix
2. Designing the framework for single crowns
2.1 Anterior crowns
2.2 Posterior crowns with a flat occlusal preparation
2.3 Posterior crowns with a deep occlusal preparation
2.4 Posterior crowns without supporting cusps
3. Designing the pontic
3.1 Pontic
3.2 Joint face of the connector
3.3 Pontic/abutment contact layer
4. Trimming the margins of Vectris frameworks
5. Placing Vectris Pontic into the Transil matrix
The indicated numbers of Pontic strips are reference values and may differ depending
on the situation in question.
F R A M E W O R K D E S I G N
✔
indicated
✔
*
advisable
contraindicated